Research on Non-Invasive Voltage Measurement Method Based on Impedance Adaptation

Gang Ao,Jie Tang,Dongdong Li,Wenbin Zhang,Le Yang,Zhipeng Xu
DOI: https://doi.org/10.1080/10584587.2024.2324681
2024-10-25
Integrated Ferroelectrics
Abstract:Transformer-based contact voltage measurement requires electrically charged installation during use. Moreover, there are problems with large sizes and restricted installation locations. The current non-contact voltage measurement technology is based on the principle of capacitive coupling in measurement. The capacitance between the probe and the wire is affected by the diameter of the wire and the insulation material. This results in an unstable sensor gain relationship, which leads to low measurement accuracy. This paper proposes a non-contact multi-wire adaptive voltage measurement method, and self-calibration of the sensor gain is achieved through practical measurements. First, the basic principle of capacitively coupled voltage measurement is introduced, from which the existing problems are condensed. An impedance-based adaptive method is proposed, based on which a new sensor probe is developed. The accuracy test reveals that the maximum relative error of voltage amplitude is 0.89 percent, the relative error of phase is 0.38%, and the relative phase error is within 1 degree for a specified voltage range (100 V-300V). The scenario adaptability test shows that the maximum relative error is 1.7% when performing tests on different types of lines. This sensor has the advantages of compactness, convenience, low cost, and high practicality.
engineering, electrical & electronic,physics, condensed matter, applied
What problem does this paper attempt to address?