Abstract:Power quality of the residential distribution systems receives lots of attention as the penetration of household power-electronic appliances has been significantly increased in recent years. Existing current measurement technologies are only able to measure either a single wire (e.g., clamp-on probe) or two-wire cables using a sensor array, which is large in size and difficult to install. A non-invasive, integrated, compact electro-magnetic sensor for the two-wire residential service cables is proposed, designed and applied to monitor household harmonic distortion. It does not need to break the cable enclosure and is convenient to deploy by attaching the sensor to the cable. Its accuracy is proven by a series of comparisons with standard measuring instruments. And harmonic distortion analysis is made using the measure waveforms of various household appliances.