A Self-Decoupling Contactless Overvoltage Measurement Method Based on Optimization of Measuring Point

Xiaojun Yan,Jingang Wang,Zeliang Shen,Pengcheng Zhao,Xiang Li,Qian Wang
DOI: https://doi.org/10.1109/tim.2022.3159006
IF: 5.6
2022-01-01
IEEE Transactions on Instrumentation and Measurement
Abstract:Contactless overvoltage measurement sensor has good foreground in the application of the power system, and however, the difference in the installation position of the sensor will directly affect the stability of the measurement system. Therefore, it is essential to improve the overall measurement effect by selecting an appropriate measuring point. In this article, first, we proposed a new self-decoupling method based on the simplified matrix with the position parameters of the measuring point and applied it in the measurement of three-phase transient overvoltage. Then, we obtained the 3-D electric field ( <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.776ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 764.5 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-45" x="0" y="0"></use></g></svg></span> -field) distribution characteristic under the different simulated overvoltage signals and preliminarily analyzed the measuring effect of the various measuring points distributed in the axial and radial direction of the overhead line. Furthermore, we proposed the gradient optimizing method with a calculation and analysis process for the selection of the measuring point. Finally, taking the three-phase horizontal distributed transmission lines as an example, we calculated the voltage coefficient matrix at various selected points, estimated the uncertainty contributions, and accomplished the test through the overvoltage experimental platform. From the result, the relative amplitude error of the overvoltage signal measured by the sensor installed at the optimal measuring point is less than 3.50%, the relative expanded uncertainty of the test at the optimal point is about 8.74%, and the values are much smaller than those of other measuring points, which proved the effectiveness of the proposed method.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-45" d="M492 213Q472 213 472 226Q472 230 477 250T482 285Q482 316 461 323T364 330H312Q311 328 277 192T243 52Q243 48 254 48T334 46Q428 46 458 48T518 61Q567 77 599 117T670 248Q680 270 683 272Q690 274 698 274Q718 274 718 261Q613 7 608 2Q605 0 322 0H133Q31 0 31 11Q31 13 34 25Q38 41 42 43T65 46Q92 46 125 49Q139 52 144 61Q146 66 215 342T285 622Q285 629 281 629Q273 632 228 634H197Q191 640 191 642T193 659Q197 676 203 680H757Q764 676 764 669Q764 664 751 557T737 447Q735 440 717 440H705Q698 445 698 453L701 476Q704 500 704 528Q704 558 697 578T678 609T643 625T596 632T532 634H485Q397 633 392 631Q388 629 386 622Q385 619 355 499T324 377Q347 376 372 376H398Q464 376 489 391T534 472Q538 488 540 490T557 493Q562 493 565 493T570 492T572 491T574 487T577 483L544 351Q511 218 508 216Q505 213 492 213Z"></path></defs></svg>
engineering, electrical & electronic,instruments & instrumentation
What problem does this paper attempt to address?