Rapid Determination of Tetracyclines in Drinking and Environmental Waters using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry

Tongtong Zhang,Xiangyang Zhang,Jiangmei Yu,Hongmei Hu,Pengfei He,Zhenhua Li,Yi Fang,Tiejun Li,Yuanming Guo
DOI: https://doi.org/10.3390/molecules29122921
IF: 4.6
2024-06-20
Molecules
Abstract:The abuse and irrational use of tetracyclines (TCs) in human medicine and animal husbandry has become a serious concern, affecting the ecological environment and human health. The aim of this study was to develop a sensitive and selective method using fully automatic solid-phase extraction coupled with ultra-performance liquid chromatography–tandem mass spectrometry for the determination of twelve TCs in water. Four isotope-labeled internal standards for TCs were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the optimum experimental conditions found were 1.0 L water sample with 0.5 g/L Na2EDTA (pH 3.0) extracted and enriched by CNW HLB cartridge and eluted by 4 mL of acetone:methanol (v/v, 1:1). The enrichment factors were up to 798−1059 but only requiring about 60 min per six samples. Under the optimized conditions, the linearity of the method ranged from 0.2 to 100 μg/L for 12 TCs, the detection limits were as low as 0.01−0.15 ng/L, and the recoveries were in the range of 70%–118%, with relative standard deviations less than 15%. The developed method can be successfully utilized for the determination of 12 TCs in pure water, tap water, river water, and mariculture seawater. In summary, three and six TCs were detected in river water and mariculture seawater, respectively, with total concentrations of 0.074–0.520 ng/L (mean 0.248 ng/L) and 0.792–58.369 ng/L (12.629 ng/L), respectively. Tetracycline (TC) and oxytetracycline (OTC) were the dominant TCs in river water, while doxytetracycline (DXC) and OTC were dominant in mariculture seawater.
chemistry, multidisciplinary,biochemistry & molecular biology
What problem does this paper attempt to address?
This paper aims to develop a sensitive and selective method for the determination of tetracycline antibiotics (TCs) in drinking water and environmental water samples. Specifically, the objective of the study is to establish a fully automated solid-phase extraction combined with ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC–MS/MS) method for the detection of 12 tetracycline antibiotics. To address the issue of matrix effects, four isotopically labeled internal standards were used to correct the TCs in the study. Under optimized conditions, the method exhibited a good linear range, low detection limits (0.01-0.15 ng/L), high recovery rates (70%-118%), and relative standard deviations of less than 15%. Additionally, the method was successfully applied to the analysis of pure water, tap water, river water, and seawater aquaculture samples, detecting different types of tetracycline antibiotics. Among them, tetracycline (TC) and oxytetracycline (OTC) were predominant in river water, while doxycycline (DXC) and oxytetracycline (OTC) were predominant in seawater aquaculture samples. In summary, this study provides a new method for effectively monitoring tetracycline antibiotic residues in the environment.