Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples

Ning Liang,Peiting Huang,Xiaohong Hou,Zhen Li,Lei Tao,Longshan Zhao
DOI: https://doi.org/10.1007/s00216-015-9284-z
2016-01-15
Analytical and Bioanalytical Chemistry
Abstract:A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min−1, and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1–1000 ng mL−1 (sulfamethoxazole, cefuroxime axetil), 5–1000 ng mL−1 (tinidazole), 10–1000 ng mL−1 (chloramphenicol), 2-1000 ng mL−1 (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1–400 ng mL−1 (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL−1, respectively. The relative recoveries of the target analytes were in the range from 64.16 % to 99.80 % with relative standard deviations between 0.7 and 8.4 %. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.
chemistry, analytical,biochemical research methods
What problem does this paper attempt to address?
This paper aims to solve the problem of ultra - trace detection of antibiotics in the water environment. Specifically, the researchers developed a method combining solid - phase extraction (SPE) with dispersive liquid - liquid micro - extraction (DLLME), and combined with ultra - high - performance liquid chromatography - tandem mass spectrometry (UHPLC - MS/MS) technology for the ultra - trace determination of 10 antibiotics in environmental water samples. This method can not only effectively enrich the ultra - trace antibiotics in water samples, but also significantly reduce the matrix effect and improve the sensitivity and accuracy of detection. By optimizing experimental conditions, such as pH value, type and volume of extraction solvent, etc., this method has been successfully applied in various water samples (drinking water, tap water, river water, influent and effluent wastewater), showing a good linear range, repeatability and precision. The limits of detection (LOD) and limits of quantification (LOQ) have reached very low levels, which are below 1.67 ng/mL and 5.57 ng/mL respectively, and the relative recoveries are between 64.16% and 99.80%, indicating that this method has high sensitivity and repeatability and is suitable for the detection and analysis of antibiotics in actual water samples.