The effects of counter ion on CO 2 capture performance of amino acid salt solutions for direct air capture applications
Mohamed H. Abdellah,Ali Kiani,William Conway,Graeme Puxty,Paul Feron
DOI: https://doi.org/10.1016/j.seppur.2024.130390
IF: 8.6
2024-11-13
Separation and Purification Technology
Abstract:Direct CO 2 capture from the atmosphere has received growing attention driven by the imperative of achieving global net-zero emission targets. Amino acid salt solutions are promising candidates for liquid-based direct air capture processes. Utilised as a neutralized salt by reacting initially with hydroxides, it has been speculated that their performance may vary with the type of counter ion present in the solution. This work investigates the influence of counter ions, potassium, sodium, and lithium, of different amino acid salt solutions on the physical properties, the CO 2 absorption capacities, and the CO 2 absorption kinetics under atmospheric CO 2 concentration levels. The potassium-based amino acid solutions exhibited significantly lower viscosities and mildly elevated densities compared to sodium- and lithium-based solutions. At 25 °C, the potassium-prolinate solution demonstrated the highest viscosity (8.5 mPa s), whereas potassium-glycinate exhibited the lowest viscosity (2.5 mPa s). Additionally, potassium-based solutions consistently displayed the highest CO 2 mass transfer coefficients, followed by sodium- and lithium-based solutions. The CO 2 mass transfer coefficient was the highest for potassium-prolinate (2.99 mmol m −2 s −1 kPa −1 ) with the lowest rate observed for potassium-β-alaninate (1.68 mmol m −2 s −1 kPa −1 ). Interestingly, the type of counter ion had minimal impact on the CO 2 absorption capacity, with potassium-based solutions exhibiting only a slightly elevated capacity compared to sodium- and lithium-based solutions. Specifically, potassium-lysinate displayed the highest CO 2 absorption capacity (0.7 mol CO 2 /mol amine), while potassium-β-alaninate showed the lowest (0.65 mol CO 2 /mol amine). It should be noted that all lithium-based solutions of all amino acids formed precipitates at the equilibrium CO 2 absorption capacity. From a practical and operational perspective, these findings suggest that the potassium salt solution of amino acids would be the optimal choice for direct air capture applications due to their enhanced solubility and CO 2 mass transfer rates compared to the corresponding sodium and lithium counter ion salt solutions.
engineering, chemical