An Experimental Configuration to Study High-Enthalpy Radiating Flows Under Nonequilibrium De-excitation

Zhuo Liu,Sangdi Gu,Tiantian Chen,Jiaao Hao,Chih-yung Wen,Qiu Wang
2024-09-26
Abstract:This paper presents an experimental configuration to study high-enthalpy radiating flows under nonequilibrium de-excitation. A general design method is introduced, combiningtheoretical analysis and numerical simulations to tailor the flow conditions for various research objectives. The implementation involves considerations of the shock tube condition, the arrangement configuration, and the effective measurement zone. The interplay between shock tube condition and aerofoil geometry generates diverse de-excitation patterns. The shock tube test time, transition onset location, and radiance intensity determine the effective measurement zone. An example utilizing N2 as the test gas demonstrates the method, achieving one-dimensional flow with thermal nonequilibrium and chemical freezing along the centerline, validating the method's effectiveness. An effective measurement zone of 200 mm is obtained under this condition, and the primary constraint under high-enthalpy conditions is the limited shock tube test time due to the high shock velocity and low fill pressure.
Fluid Dynamics
What problem does this paper attempt to address?