A 25-micron single photon sensitive kinetic inductance detector
Peter K. Day,Nicholas F. Cothard,Christopher Albert,Logan Foote,Elijah Kane,Byeong H. Eom,Ritoban Basu Thakur,Reinier M.J. Janssen,Andrew Beyer,Pierre Echternach,Sven van Berkel,Steven Hailey-Dunsheath,Thomas R. Stevenson,Shahab Dabironezare,Jochem J.A. Baselmans,Jason Glenn,C. Matt Bradford,Henry G. Leduc
2024-05-15
Abstract:We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
Instrumentation and Methods for Astrophysics,Instrumentation and Detectors