A 25-micron single photon sensitive kinetic inductance detector

Peter K. Day,Nicholas F. Cothard,Christopher Albert,Logan Foote,Elijah Kane,Byeong H. Eom,Ritoban Basu Thakur,Reinier M.J. Janssen,Andrew Beyer,Pierre Echternach,Sven van Berkel,Steven Hailey-Dunsheath,Thomas R. Stevenson,Shahab Dabironezare,Jochem J.A. Baselmans,Jason Glenn,C. Matt Bradford,Henry G. Leduc
2024-05-15
Abstract:We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
Instrumentation and Methods for Astrophysics,Instrumentation and Detectors
What problem does this paper attempt to address?
This paper aims to solve the problem of high - sensitivity photon detection in the far - infrared band (especially at a wavelength of 25 micrometers). Specifically, the researchers developed a Kinetic Inductance Detector (KID) for single - photon detection under extremely low background light levels and wide - dynamic - range detection in the integration mode. The following are the main problems that this research attempts to solve: 1. **Single - photon sensitivity**: - Under low - light - flux conditions, the detector can distinguish a single photon with a wavelength of 25 micrometers. This is very important for applications requiring extremely high sensitivity, such as far - infrared instruments in space telescopes. 2. **Wide - dynamic - range integration mode**: - Under higher - light - flux conditions, the detector can maintain photon - noise - limited performance (from 70 zW to 200 fW) within an absorption power range exceeding six orders of magnitude. This makes the detector suitable for light sources with various intensities. 3. **Low - frequency stability**: - The detector exhibits high stability under optical loading, and the power spectrum is flat up to 1 mHz. This stability is crucial for long - time integration measurements and can be used to detect small changes in light flux. 4. **High - energy conversion and self - recombination constant**: - The researchers determined the operating parameters of the detector, including the efficiency of converting incident optical power into quasiparticles in the aluminum - absorbing element and the quasiparticle self - recombination constant. These parameters are very critical for optimizing the detector performance. ### Formula summary - **Photon energy resolution**: \[ R=\frac{\langle E\rangle}{\Delta E_{\text{FWHM}}} \] where \(\langle E\rangle\) is the average energy and \(\Delta E_{\text{FWHM}}\) is the full - width - at - half - maximum energy resolution. - **Fano limit**: \[ R_{\text{FANO}}=\frac{1}{2}\sqrt{2\log 2}\frac{\eta_{\text{pb}}E_\gamma}{\Delta F}\approx 8 \] where \(\eta_{\text{pb}}\) is the Cooper - pair - breaking efficiency, \(E_\gamma\) is the photon energy, and \(\Delta F\) is the energy - distribution width. - **Quasiparticle production efficiency**: \[ \eta_{\text{pb}}=\frac{\Delta_0 N_{\text{qp}}}{h\langle\nu\rangle}\frac{\langle\delta x\rangle}{(\delta x / \delta N_{\text{qp}})} = 0.32 \] where \(\Delta_0\) is the superconducting energy gap, \(N_{\text{qp}}\) is the number of generated quasiparticles, \(\langle\nu\rangle\) is the average frequency, and \(\langle\delta x\rangle\) is the average pulse height. - **Noise - equivalent power (NEP)**: \[ \text{NEP}_{\text{shot}}=\sqrt{2h\nu P_{\text{abs}}} \] where \(h\) is Planck's constant, \(\nu\) is the frequency, and \(P_{\text{abs}}\) is the absorption power. Through these formulas and experimental results, the researchers demonstrated the excellent performance of this KID detector in single - photon detection and wide - dynamic - range integration mode, and verified its potential in far - infrared - band applications.