Characterization of a Far-Infrared Kinetic Inductance Detector Prototype for PRIMA

Steven Hailey-Dunsheath,Sven van Berkel,Andrew E. Beyer,Logan Foote,Reinier M. J. Janssen,Henry G. LeDuc,Pierre M. Echternach,Charles M. Bradford,Jochem J.A. Baselmans,Shahab Dabironezare,Peter K. Day,Nicholas F. Cothard,Jason Glenn
2024-04-18
Abstract:The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background afforded by a cold telescope, spectroscopy with PRIMA requires detectors with a noise equivalent power (NEP) better than $1 \times 10^{-19}$ W Hz$^{-1/2}$. To meet this goal we are developing large format arrays of kinetic inductance detectors (KIDs) to work across the $25-250$ micron range. Here we present the design and characterization of a single pixel prototype detector optimized for $210$ micron. The KID consists of a lens-coupled aluminum inductor-absorber connected to a niobium interdigitated capacitor to form a 2 GHz resonator. We have fabricated a small array with 28 KIDs, and we measure the performance of one of these detectors with an optical loading in the $0.01 - 300$ aW range. At low loading the detector achieves an NEP of $9\times10^{-20}$ W Hz$^{-1/2}$ at a 10 Hz readout frequency, and the lens-absorber system achieves a good optical efficiency. An extrapolation of these measurements suggest this detector may remain photon noise limited at up to 20 fW of loading, offering a high dynamic range for PRIMA observations of bright astronomical sources.
Physics
What problem does this paper attempt to address?