Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors

D. C. Moore,S. R. Golwala,B. Bumble,B. Cornell,P. K. Day,H. G. LeDuc,J. Zmuidzinas
DOI: https://doi.org/10.1063/1.4726279
IF: 4
2012-06-04
Applied Physics Letters
Abstract:We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with ≲ 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σE = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for ∼1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.
physics, applied
What problem does this paper attempt to address?