The first cut is the cheapest: optimizing Athena/X-IFU-like TES detectors resolution by filter truncation

M. Teresa Ceballos,Nicolás Cardiel,Beatriz Cobo,Stephen J. Smith,Michael C. Witthoeft,Philippe Peille,Malcolm S. Durkin
DOI: https://doi.org/10.1007/s10686-024-09930-2
2024-03-26
Abstract:The X-ray Integral Field Unit (X-IFU) instrument on the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors designed to provide spatially-resolved high-resolution spectroscopy. The onboard reconstruction software provides energy, spatial location and arrival time of incoming X-ray photons hitting the detector. A new processing algorithm based on a truncation of the classical optimal filter and called 0-padding, has been recently proposed aiming to reduce the computational cost without compromising energy resolution. Initial tests with simple synthetic data displayed promising results. This study explores the slightly better performance of the 0-padding filter and assess its final application to real data. The goal is to examine the larger sensitivity to instrumental conditions that was previously observed during the analysis of the simulations. This 0-padding technique is thoroughly tested using more realistic simulations and real data acquired from NASA and NIST laboratories employing X-IFU-like TES detectors. Different fitting methods are applied to the data, and a comparative analysis is performed to assess the energy resolution values obtained from these fittings. The 0-padding filter achieves energy resolutions as good as those obtained with standard filters, even with those of larger lengths, across different line complexes and instrumental conditions. This method proves to be useful for energy reconstruction of X-ray photons detected by the TES detectors provided proper corrections for baseline drift and jitter effects are applied. The finding is highly promising especially for onboard processing, offering efficiency in computational resources and facilitating the analysis of sources with higher count rates at high resolution.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
### What problem does this paper attempt to solve? This paper aims to optimize the energy resolution of Transition - Edge Sensor (TES) detectors in the X - ray Integral Field Unit (X - IFU) instrument for the Athena X - ray Observatory in the future mission of the European Space Agency (ESA). Specifically, the research focuses on reducing the computational cost through a filtering truncation technique called "0 - padding" without compromising the energy resolution. #### Main problems: 1. **Trade - off between computational cost and energy resolution**: Although traditional optimal filtering techniques can provide high energy resolution, their computational cost is relatively high, especially when dealing with data with a high count rate. Therefore, a method that can maintain high energy resolution while reducing computational cost needs to be found. 2. **Limitations of existing filtering methods**: Existing filtering methods (such as FULL and SHORT filters) have some limitations in practical applications. For example, they are highly sensitive to changes in instrument conditions, especially the baseline drift problem caused by temperature changes. Therefore, it is necessary to evaluate the performance of new methods (such as 0 - padding) under such conditions. 3. **Feasibility of application to real data**: Although previous studies have shown that the 0 - padding technique performs well on synthetic data, more extensive testing and verification are still required before it is applied to real data to ensure its feasibility and stability in practical application scenarios. ### Main objectives of the paper: - **Evaluate the performance of the 0 - padding filter**: By using more realistic simulation data and real data from NASA and NIST laboratories, comprehensively evaluate the energy resolution of the 0 - padding filter under different conditions (such as different line complexes and instrument conditions). - **Compare the effects of different filtering methods**: Compare the results of the 0 - padding filter with the existing FULL and SHORT filters, and analyze its advantages and disadvantages in terms of energy resolution, computational efficiency, etc. - **Explore the influence of systematic and external factors**: Evaluate the influence of different analysis algorithms and some external factors (such as temperature changes) on the results to ensure the reliability and stability of the 0 - padding method under various conditions. ### Key conclusions: - **Effectiveness of the 0 - padding filter**: The research shows that the 0 - padding filter can significantly reduce the computational cost while maintaining the same energy resolution as the FULL filter, especially for data processing with a high count rate. - **Sensitivity to instrument conditions**: The 0 - padding filter is more sensitive to changes in instrument conditions (such as baseline drift caused by temperature changes), so these factors need to be paid special attention to in practical applications. - **Wide range of applications**: This method is not only applicable to X - IFU - type detectors, but can also be extended to other current or future TES detectors, and has broad application prospects. ### Summary: Through in - depth research and experimental verification, this paper proposes a new filtering truncation technique (0 - padding) to optimize the energy resolution of X - IFU TES detectors and significantly reduce the computational cost. This method performs well in high - count - rate data processing, but in practical applications, attention needs to be paid to its sensitivity to changes in instrument conditions.