First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

Nora Hoch,Olivia Seidel,Varghese A. Chirayath,Alfredo Enriquez,Elena Gramellini,Roxanne Guenette,I-See W. Jaidee,Kevin Keefe,Shahab Kohani,Shion Kubota,Hany Mahdy,Austin McDonald,Yuan Mei,Peng Miao,F. Mitch Newcomer,David Nygren,Ilker Parmaksiz,Michael Rooks,Iakovos Tzoka,Wenzhao Wei,Jonathan Asaadi,James B.R. Battat
2024-04-16
Abstract:We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.
High Energy Physics - Experiment,Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the measurement of electron transverse diffusion in a gas Time Projection Chamber (TPC). Specifically, the research team has developed a multi - channel prototype device named Q - Pix for measuring electron transverse diffusion in P - 10 gas (90% Ar, 10% CH₄) in a laboratory - scale TPC. The Q - Pix technology adopts a novel pixelated signal - capture and - digitization method, that is, detecting signals by comparing the output of an integrating capacitor with a threshold voltage. When the threshold is reached, the comparator sends a "reset" signal, triggering the integrating capacitor to discharge. This method can accurately measure the average current within the time interval of each pixel and the total collected charge. The main objective of the paper is to verify whether the Q - Pix technology can successfully reconstruct the ionization topology in the TPC and can be applied on a large scale in a low - temperature environment to meet the requirements of future large - scale TPC experiments. In addition, the research also aims to verify the simulation results through experimental data, especially the electron transverse diffusion characteristics under different operating pressures (200–1500 Torr). Through these measurements, the researchers hope to prove the effectiveness and reliability of the Q - Pix technology in low - event - rate scenarios, such as possible applications in deep - underground neutrino experiments (such as the DUNE far - detector). This will not only help to improve the resolution and background - suppression ability of the TPC, but also reduce the data - transmission burden and improve the sensitivity of low - energy events.