GAMPix: a novel fine-grained, low-noise and ultra-low power pixelated charge readout for TPCs

Tom Shutt,Bahrudin Trbalic,Aldo Pena-Perez,Steffen Luitz,Mark Convery,Angelo Dragone,Lorenzo Rota,Dietrich R. Freytag,Dionisio Doering,Filippo Mele,Miriam Moore,Hiro Tanaka,Yun-Tse Tsai
2024-02-01
Abstract:We report on the development of a novel pixel charge readout system, Grid Activated Multi-scale pixel readout (GAMPix), which is under development for use in the GammaTPC gamma ray instrument concept. GammaTPC is being developed to optimize the use of liquid argon time projection chamber technology for gamma ray astrophysics, for which a fine grained low power charge readout is essential. GAMPix uses a new architecture with coarse and fine scale instrumented electrodes to solve the twin problems of loss of measured charge after diffusion, and high readout power. Fundamentally, it enables low noise and ultra low power charge readout at the spatial scale limited by diffusion in a time projection chamber, and has other possibly applications, including future DUNE modules.
Instrumentation and Detectors,Instrumentation and Methods for Astrophysics,High Energy Physics - Experiment
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to solve the problem of achieving fine - grained, low - noise and ultra - low - power charge readout in the Liquid Argon Time Projection Chamber (LAr TPC). Specifically, the paper proposes a new charge readout system architecture - Grid Activated Multi - scale Pixel Readout (GAMPix), for the Gamma TPC gamma - ray instrument concept. The Gamma TPC is developed to optimize the application of Liquid Argon Time Projection Chamber technology in gamma - ray astrophysics, where fine - grained and low - power charge readout is a key requirement. ### Specific problems 1. **Charge loss due to diffusion**: - In the TPC, as electrons will diffuse during the drift process, the charge distribution becomes wider, and some charges may be below the sensor's threshold and thus undetectable. This not only affects the spatial resolution but also leads to signal loss, especially more seriously in low - energy events. 2. **High - power consumption problem**: - Fine - grained charge readout requires a large number of channels, and each channel needs a low - noise readout circuit. This results in a very high overall power consumption, especially in space applications where the power consumption requirements are very strict. For example, in the Gamma TPC, if the traditional pixel readout scheme is used, the power density will reach 1kW/m², far exceeding the capacity of the spacecraft cooling system. ### Solutions The GAMPix architecture solves the above problems in the following ways: 1. **Two - layer readout system**: - **Coarse readout electrodes**: Use cross - wire electrodes (coarse grid) with a 1 - centimeter spacing. These electrodes can measure the total charge amount and are not affected by diffusion. These electrodes provide the basis for integral charge measurement. - **Fine readout electrodes**: Use pixel electrodes with a 500 - micron spacing. These electrodes provide high - resolution track imaging. By combining the data of the coarse grid and pixel electrodes, the total charge amount can be recovered and a high - resolution track image can be obtained. 2. **Trigger mechanism**: - The coarse grid electrodes are not only used to measure the total charge but also can provide a trigger signal. When a charge is detected, only the relevant pixel chips will be activated, thus greatly reducing the power consumption. This trigger mechanism enables GAMPix to meet strict power consumption requirements while maintaining low noise. 3. **Low - noise and low - power ASIC design**: - A low - noise, low - power pixel ASIC has been developed. This ASIC has the ability to switch power at the microsecond level and can be activated and stabilized in a short time to capture charge signals. Preliminary simulation results show that this ASIC can achieve high - gain, fast - response and low - noise performance under low - temperature conditions. ### Conclusion Through innovative design, the GAMPix architecture has successfully solved two major challenges of fine - grained, low - noise charge readout in the TPC: charge loss due to diffusion and high - power consumption problems. This technology is not only applicable to the Gamma TPC but also is expected to be applied in other fields, such as the DUNE experiment.