Impact of mechanical disturbances to the placement of reference light in Fourier transform interferometers

Muqian Wen
2023-11-28
Abstract:Fourier transform interferometers usually need a dedicated reference light to track optical path difference changes precisely. There are a few different ways to incorporate the reference light into the optical system. This paper conducted experiments to give a test of how different ways of incorporating reference light are affected by mechanical disturbances. It found that placing the reference light in different path than the test light can be very sensitive to mechanical disturbance errors while propagating the reference light together with the test light can be very robust against mechanical vibrations of optical components. We hope that this study can be useful to researchers to help make better design choices in their experiments.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem this paper attempts to address is: how different methods of introducing reference light in a Fourier transform interferometer are affected by mechanical disturbances. Specifically, the authors experimentally evaluate the impact of mechanical vibrations on the accuracy of measurement results when introducing reference light in three different ways (co-propagation, parallel propagation, and separate propagation). The aim of the study is to provide researchers with better design choices to improve experimental accuracy. ### Background of the Paper A Fourier transform interferometer typically requires a dedicated reference light to accurately track changes in optical path difference. The reference light can be introduced in the following three ways: 1. **Co-propagation**: The reference light and the measurement light are combined into one beam and propagate together. 2. **Parallel propagation**: The reference light and the measurement light propagate in parallel but do not overlap. 3. **Separate propagation**: The reference light and the measurement light propagate through different optical paths. Each method has its advantages and disadvantages, but there is currently no clear research indicating which method performs best under mechanical disturbances. ### Research Objective The authors aim to experimentally evaluate the performance of these three methods under mechanical vibrations to help researchers make better choices when designing experiments. Specific objectives include: - Assessing the stability of different reference light introduction methods under mechanical vibrations. - Providing quantitative data support to help researchers optimize experimental design. ### Experimental Design The authors constructed multiple Fourier transform interferometers and tested the three aforementioned methods of introducing reference light. The experimental equipment included common optical instruments such as helium-neon lasers, polarizers, and beam splitters. During the experiments, the authors recorded the interference patterns under different propagation methods and analyzed the impact of mechanical vibrations on the measurement results. ### Experimental Results 1. **Co-propagation**: The results showed that the co-propagation method has high robustness to mechanical vibrations and can effectively cancel out errors caused by vibrations. 2. **Parallel propagation**: The parallel propagation method also demonstrated good stability in the experiments. Although there were some minor vibration errors, these errors were within acceptable limits. 3. **Separate propagation**: The separate propagation method performed the worst in the experiments. Even a 1-millimeter-long interference pattern could not work properly, mainly because mechanical vibrations caused displacement of the optical components. ### Discussion - **Impact of Mechanical Vibrations**: Mechanical vibrations are the main factor affecting the separate propagation method. The translation stages and other optical components used in the experiments generate vibrations, which are transmitted to other optical components, leading to inaccurate measurement results. - **Improvement Measures**: To overcome the impact of mechanical vibrations, some measures can be taken, such as using actively damped optical platforms, more stable mount designs, and step-scanning mechanisms. However, these measures may increase the complexity and cost of the experiments. - **Theoretical Analysis**: Theoretically, the co-propagation and parallel propagation methods have higher robustness to mechanical vibrations because the reference light and the measurement light experience the same disturbances, thereby canceling each other out. ### Conclusion This study shows that mechanical vibrations have a significant impact on the measurement results of a Fourier transform interferometer. When using conventional optical equipment, the separate propagation method is easily affected by mechanical vibrations, while the co-propagation and parallel propagation methods are more stable. Therefore, when mechanical vibrations are a concern, the separate propagation method should be chosen with caution or avoided if possible. It is hoped that this study will provide useful references for Fourier transform spectroscopy and other experiments that require precise tracking of translation stage movements.