Cooling power analysis of a small scale 4 K pulse tube cryocooler driven by an oil-free low input power Helium compressor

Jack-Andre Schmidt,Bernd Schmidt,Jens Falter,Jens Hoehne,Claudio Dal Savio,Sebatsian Schaile,Andre Schirmeisen
2023-11-01
Abstract:Here we report the performance of a small scale 4 K pulse tube cryocooler operating with a low input power reaching a minimum temperature of 2.2 K, as well as a cooling capacity of over 240 mW at 4.2 K. The compressor is air cooled and can be supplied by single phase power sockets. With an input power of about 1.3 kW the coefficient of performance reaches values of up to 185 mW/kW, which is among the highest currently reported values for small to medium power pulse tubes. The combination of an oil-free Helium compressor and low maintenance pulse tube cryocooler provides a unique miniaturized, energy efficient and mobile cooling tool for applications at 4 K and below.
Materials Science,Applied Physics,Quantum Physics