Tuning of Nuclear Spectroscopic Telescope Array (NuSTAR) Application Specific Integrated Circuits (ASICs) to improve low energy threshold of future Hard X-ray Imaging Detectors

Daniel P. Violette,Branden Allen,Jaesub Hong,Hiromasa Miyasaka,Jonathan Grindlay
DOI: https://doi.org/10.1117/1.JATIS.9.1.016001
2023-08-18
Abstract:Detector commanding, processing and readout of spaceborne instrumentation is often accomplished with Application Specific Integrated Circuits (ASICs). The ASIC designed for the Nuclear Spectroscopic Telescope Array (NuSTAR) mission (NuASIC) enables future tiled CdZnTe (CZT) detector array readout for x-ray detectors such as the High Resolution Energetic X-ray Imager (HREXI). Modified NuASIC gain settings have been implemented for HREXI's broader targeted imaging energy range (3-300 keV) compared to NuSTAR (2-79 keV), which may require updated NuASIC internal parameters for optimal energy resolution. To reach HREXI's targeted low energy threshold, we have also enabled the NuASIC's "Charge Pump Mode" (CPM), which introduces an additional tuning parameter. In this paper, we describe the mechanics of the NuASIC's adjustable parameters and use our recently developed ASIC Test Stand (ATS) to probe a "bare" NuASIC using its internal test pulser. We record the effects of parameter tuning on the device's electronics noise and low energy threshold and report the optimal set of parameters for HREXI's updated gain setting. We detail a semi-automated procedure to derive the optimal parameters for each of HREXI's large area, closely tiled NuASIC/CZT detectors to expedite instrument integration.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **How to improve the low - energy threshold of future hard X - ray imaging detectors by adjusting the parameters of the Nuclear Spectroscopic Telescope Array (NuSTAR) Application - Specific Integrated Circuits (ASICs)**. Specifically, the paper focuses on optimizing the internal parameters of the NuSTAR ASIC (referred to as NuASIC for short) for the High - Resolution Energy X - ray Imager (HREXI). The goal of HREXI is to achieve a wider energy range (3 - 300 keV), while the energy range of NuSTAR is 2 - 79 keV. To achieve this goal, the following improvements need to be made to NuASIC: 1. **Adjust the gain settings**: HREXI needs to work in a wider energy range, so the gain settings of NuASIC need to be adjusted to ensure that it does not saturate in the extended dynamic energy range. 2. **Enable the "Charge Pump Mode" (CPM)**: CPM can further reduce the quiescent current of the pre - amplifier output, thereby suppressing detector noise and improving energy resolution. This introduces an additional tuning parameter. 3. **Optimize internal parameters**: By adjusting multiple internal parameters of NuASIC (such as vnl1sel, vnl2sel, vpl2sel, vpl3sel, and 4Vsel, etc.), to achieve the best energy resolution and low - energy threshold. 4. **Develop an automated calibration process**: Since HREXI contains a large number of CZT/ASIC detector arrays (256 detectors), a semi - automated parameter selection method needs to be developed to save time and cost. ### Main research contents 1. **Parameter adjustment mechanism**: - The paper describes in detail the adjustable parameters of NuASIC and their effects on electronic noise and low - energy threshold. - Use the newly developed ASIC test platform (ATS) to explore individual NuASICs and record the effects of parameter adjustments. 2. **Experimental results**: - By adjusting the vnl1sel and vnl2sel parameters, the resolution of the pixel channels can be significantly improved in both normal mode and CPM. - In CPM mode, by optimizing the 4Vsel parameter, the voltage ramp - up effect of the pre - amplifier output can be further reduced, thereby improving the resolution and low - energy threshold. 3. **Optimized parameter selection**: - Determine the optimal parameter combinations suitable for HREXI, including the bias current settings of the pre - amplifier and the shaping amplifier. - Verify the parameter sensitivity under different temperature conditions and provide a reference for future flight missions. ### Conclusion Through the systematic adjustment and optimization of NuASIC parameters, the paper has successfully improved the performance of the HREXI detector in a wide energy range, especially achieving significant improvements in the low - energy threshold and energy resolution. These optimization measures will contribute to the design and application of future hard X - ray imaging detectors, and are of particular significance for multi - messenger astronomy research.