The SiFi-CC detector for beam range monitoring in proton therapy -- characterization of components and a prototype detector module

Katarzyna Rusiecka
2023-06-19
Abstract:The following thesis presents research which constitutes the first steps towards the construction of a novel SiFi-CC detector intended for real-time monitoring of proton therapy. The detector construction will be based on inorganic scintillating fibers and silicon photomultipliers. The scope of the presented thesis includes the design optimization of the components of the proposed detector, as well as the construction, characterization, and tests of a prototype. The design optimization comprised an extensive systematic comparison of chosen inorganic scintillating materials, different types of scintillator surface modifications (wrappings and coatings), and different types of interface materials ensuring optical contact between the scintillators and the photodetector. The propagation of scintillating light in all investigated samples was described using two models: the exponential light attenuation model (ELA), and the exponential light attenuation model with light reflection (ELAR). The two models yielded the corresponding methods for energy and position reconstruction. Furthermore, the samples were investigated for energy and position resolution, light collection, and timing properties. Based on the results obtained from the optimization study, the detector prototype was constructed. Prototype tests were performed with two different photodetectors and data acquisition systems. The performance of the prototype was evaluated using the same metrics as in the case of single-fiber measurements. The best results were obtained in measurements with Philips Digital Photon Counting photosensor and the Hyperion platform, yielding a position resolution of 33.38 mm and an energy resolution of 7.73 %. The results obtained are satisfactory and sufficient for the successful operation of the proposed SiFi-CC detector.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve real - time monitoring of the beam range during proton therapy. Specifically, the research aims to develop a new - type SiFi - CC detector for real - time monitoring in proton therapy. The work of the paper mainly includes: 1. **Detector Design and Optimization**: In the study, a systematic comparison was made of different types of inorganic scintillation materials, scintillator surface modification methods (such as wrapping and coating), and different interface materials to ensure optical contact between the scintillator and the photodetector. These efforts were made to optimize the design of the detector components and improve the performance of the detector. 2. **Construction and Testing of the Prototype Detector**: Based on the results of the above - mentioned optimization research, a prototype detector was constructed and tested using two different photodetectors and data acquisition systems. The test evaluated key performance indicators such as the position resolution, energy resolution, light collection efficiency, and time characteristics of the prototype detector. 3. **Performance Evaluation**: Through experiments, when the prototype detector was measured using the Philips Digital Photon Counting light sensor and the Hyperion platform, the best results of a position resolution of 33.38 mm and an energy resolution of 7.73% were achieved. These results indicate that the proposed SiFi - CC detector can meet the requirements for successful operation. In conclusion, the research objective of this paper is to solve the problem of real - time monitoring of the beam range during proton therapy by designing and optimizing an innovative SiFi - CC detector, thereby improving the safety and effectiveness of treatment.