First Experimental Evaluation of a High-Resolution Deep Silicon Photon-Counting Sensor

Rickard Brunskog,Mats Persson,Zihui Jin,Mats Danielsson
2024-01-17
Abstract:Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 mm-0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this work, we present measurements of a prototype photon-counting detector that leverages the charge sharing to reach a theoretical sub-pixel resolution in the order of $1 {\mu}$m. The goal of the study is to validate our Monte-Carlo simulation using measurements, enabling further development. Approach: We measure the channel response at the MAX IV Lab, in the DanMAX beamline, with a 35 keV photon beam, and compare the measurements with a 2D Monte Carlo simulation combined with a charge transport model. Only a few channels on the prototype are connected to keep the number of wire bonds low. Results: The measurements agree generally well with the simulations with the beam close to the electrodes but diverge as the beam is moved further away. The induced charge cloud signals also seem to increase linearly as the beam is moved away from the electrodes. Conclusions: The agreement between measurements and simulations indicates that the Monte-Carlo simulation can accurately model the channel response of the detector with the photon interactions close to the electrodes, which indicates that the unconnected electrodes introduce unwanted effects that need to be further explored. With the same Monte-Carlo simulation previously indicating a resolution of around $1 {\mu}$m with similar geometry, the results are promising that an ultra-high resolution detector is not far in the future.
Medical Physics,Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to achieve sub - pixel - level resolution by exploiting the charge - sharing phenomenon in high - resolution photon - counting computed tomography (CT) detectors. Current photon - counting CT detectors have a decrease in dose efficiency and energy resolution due to charge - sharing, which limits the pixel size to be between approximately 0.3 millimeters and 0.5 millimeters. This paper presents a prototype photon - counting detector that exploits the charge - sharing phenomenon and can theoretically reach micron - level resolution (about 1 micron). The main purpose of the study is to verify the validity of Monte Carlo simulations through experimental data, thereby providing support for further development. Specifically, in this study, through experiments on the DanMAX beamline at the MAX IV Laboratory in Lund, Sweden, the channel responses of the prototype detector under a 35 keV photon beam were measured, and these measurement results were compared with two - dimensional Monte Carlo simulations combined with a charge - transport model. In the experiment, only a few channels on the prototype detector were connected to reduce the number of wire bonds. The research results show that when the beam is close to the electrode, the measurement results are basically consistent with the simulation results; but as the beam moves away from the electrode, differences begin to appear between the two. This indicates that the unconnected electrodes may introduce unnecessary effects and need further exploration. Nevertheless, since previous Monte Carlo simulations have shown that a resolution of about 1 micron can be achieved under similar geometric conditions, these results indicate a bright future for super - resolution detectors.