Characterisation of the Temperature-dependent Dark Rate of Hamamatsu R7081-100 10" Photomultiplier Tubes

Steve T. Wilson,Samuel Fargher,Robert J. Foster,Matthew Malek,Matthew Needham,Andrew Scarff,Gary D. Smith
DOI: https://doi.org/10.1088/1748-0221/18/08/P08017
2023-11-27
Abstract:Dark noise is a dominant background in photomultiplier tubes (PMTs), which are commonly used in liquid-filled particle detectors for single-photon detection to see the results of particle interactions. A major contribution to dark noise is thermionic emission from the photocathode. The dark noise of Hamamatsu R7081-100 PMTs is characterised in a temperature and purity controlled water tank, with the thermionic emission contribution isolated. The results suggest that the intrinsic dark rate of PMTs does not depend on the medium, but does follow Richardson's law of thermionic emission. There are external contributions to the overall observed PMT count rate identified, but the intrinsic PMT dark rate in water matches that measured in air.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **Dark noise characteristics of photomultiplier tubes (PMTs) in different media and their temperature dependence**. Specifically, the researchers focused on the temperature - dependent dark noise characteristics of the 10 - inch Hamamatsu R7081 - 100 photomultiplier tube in pure water. Dark noise is a kind of background signal in PMTs, mainly caused by thermionic emission. This phenomenon will lead to the generation of pulse signals in the absence of photon incidence. These background signals are particularly important for single - photon detection because they will significantly affect the accuracy of the detection results. ### Main research objectives: 1. **Measure the temperature - dependent dark noise of PMTs in pure water**: The researchers conducted experiments in a water tank with controllable temperature and purity to measure the dark noise rate of PMTs at different temperatures. 2. **Verify the intrinsic characteristics of dark noise**: Through experimental data, the researchers hope to verify whether the intrinsic dark noise rate of PMTs follows Richardson's law, that is, whether the relationship between the dark noise rate and temperature is in line with theoretical expectations. 3. **Exclude the influence of external factors**: The researchers also attempted to isolate the contribution of thermionic emission to dark noise and exclude the influence of other external factors (such as light pollution, radioactive background, etc.) on dark noise. ### Experimental methods: - **Experimental setup**: A 2000 - liter stainless - steel water tank was used. The water in the tank was purified and the temperature was controlled between 4°C and 30°C. - **Measurement process**: PMTs were completely immersed in water, and the generated pulse signals were recorded and analyzed by a series of electronic devices. The experiments were carried out at different temperatures, and each measurement lasted for 15 minutes. - **Data analysis**: Through the analysis of pulse signals, the researchers extracted the dark noise rate and verified its relationship with temperature. ### Key findings: - **Relationship between dark noise rate and temperature**: The experimental results show that the relationship between the dark noise rate of PMTs and temperature in the range of 15°C to 25°C is in line with Richardson's law. However, at temperatures below 15°C, the dark noise rate deviated somewhat, which may be due to the increased contribution of non - thermionic emission mechanisms. - **Influence of media on dark noise**: The experimental results indicate that the dark noise rate of PMTs in pure water is consistent with that in air, which shows that the intrinsic dark noise characteristics of PMTs are not affected by the medium. - **Influence of external factors**: Although the experimental system isolated external light pollution as much as possible, there were still some external factors (such as cosmic ray muons, radioactive background, etc.) contributing to dark noise. ### Conclusion: This study, through detailed experiments and data analysis, verified that the dark noise rate of PMTs in pure water is consistent with that in air and conforms to Richardson's law in the range of 15°C to 25°C. These results are of great significance for understanding the performance of PMTs in different media and optimizing the design of liquid detectors.