Abstract:Unlike influence lines, the concept of influence zones is remarkably absent within the field of structural engineering, despite its existence in the closely related domain of geotechnics. This paper proposes the novel concept of a structural influence zone in relation to continuous beam systems and explores its size numerically with various design constraints applicable to steel framed buildings. The key challenge involves explicitly defining the critical load arrangements, and is tackled by using the novel concepts of polarity sequences and polarity zones. These lead to the identification of flexural and (discovery of) shear load arrangements, with an equation demarcating when the latter arises. After developing algorithms that help identify both types of critical load arrangements, design data sets are generated and the influence zone values are extracted. The results indicate that the influence zone under ultimate state considerations is typically less than 3, rising to a maximum size of 5 adjacent members for any given continuous beam. Additional insights from the influence zone concept, specifically in comparison to influence lines, are highlighted, and the avenues for future research, such as in relation to the newly identified shear load arrangements, are discussed.
What problem does this paper attempt to address?
The paper aims to address a knowledge gap in the field of structural engineering regarding the design of continuous beam systems—the concept of influence zones. Although in other related fields of civil engineering, such as geotechnical engineering, the influence zone is an established concept used to identify the areas of engineering soil affected by substructure and superstructure construction, this concept has not been introduced in structural engineering. The paper proposes a new concept of structural influence zones, particularly in the application to continuous beam systems, and explores their size through numerical methods, considering various design constraints applicable to steel structure buildings.
The key challenge of the paper is to clearly define the critical load arrangements, which is addressed by introducing new concepts of polarity sequences and polarity zones. These concepts help identify the bending moment and the (newly discovered) shear force load arrangements, the latter of which is defined by an equation that dictates when it occurs. After developing algorithms that aid in identifying these two critical load arrangements, a design dataset was generated, and influence zone values were extracted from it. The research findings indicate that under ultimate state considerations, influence zones are typically smaller than three adjacent components, with the maximum size reaching up to five adjacent components. Moreover, additional insights were gained from the concept of influence zones compared to influence lines, and the paper also discusses directions for future research, particularly regarding the newly identified shear force load arrangements.
In summary, the main objective of the paper is to introduce the concept of influence zones in continuous beam systems through numerical methods to fill this knowledge gap in the field of structural engineering and to propose methods for addressing the challenge of identifying critical load arrangements.