Performance enhancement of a 100 watts class Tesla turbine

Arindam Mandal,Rajosik Adak,Sandeep Saha
DOI: https://doi.org/10.48550/arXiv.2301.01483
2023-01-04
Abstract:Tesla turbines are an attractive but less explored area in low-power applications. This article presents an experimental investigation of a centimeter scale Tesla turbine in bi and unidirectional outlet configuration with compressed air at 6 bar. The turbine's performance is enhanced by approximately 38% for a unidirectional outlet configuration. Furthermore, we also investigate the electrical power of the turbine in a bi-directional outlet configuration by coupling the turbine with a generator. Despite achieving higher performance in unidirectional outlet configuration, we observe substantial losses at the inlet we use for the experiment. To illustrate and improve the losses, we numerically investigate the turbine inlet at a total pressure and temperature difference of 2 bar and 50 degree K, respectively. Subsequently, we design two more nozzles and compared their performance with the nozzle we used in our experiment. Our findings suggest that nozzle 3 performs the best in delivering the highest Mach no and uniformity across the slits. This observation would help optimize the nozzle suitable for the Tesla turbine.
Fluid Dynamics
What problem does this paper attempt to address?