Transient detection of either maldistribution or flowrate change in a counter current plate-fin heat exchanger using an ARX model
Benoît Pfortner,Waseem Al Hadad,Vincent Schick,Denis Maillet,Célien Zacharie,Benjamin Rémy
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2021.121987
IF: 5.2
2022-01-01
International Journal of Heat and Mass Transfer
Abstract:Parametric models of ARX structure express the relationship between an input u ( t ) and one output y a r x ( t ) . The purpose of the study is first to identify such a transient model through temperature measurements in a calibration experiment. It relates the output, that is the temperature response at the outlet of each of the two fluids that flow inside the heat exchanger, to the temperature increase at the inlet of the hot fluid, considered as a transient thermal input. This model is validated in a different experiment and transient perturbation experiments are run with maldistribution or flowrate changes. They are processed in order to detect such structural changes with respect to the calibrated model and to get the steady state characteristics, transmittances and effectivenesses, of the exchanger. The advantages and drawbacks of this non-destructive technique, which does not rely on any heat transfer correlation, are detailed and discussed.
engineering, mechanical,thermodynamics,mechanics