Experimental investigation on chill-down process of cryogenic flow line

Lingxue Jin,Changgi Park,Hyokjin Cho,Cheonkyu Lee,Sangkwon Jeong
DOI: https://doi.org/10.1016/j.cryogenics.2016.08.006
IF: 2.134
2016-10-01
Cryogenics
Abstract:This paper describes the cryogenic chill-down experiments that are conducted on a 12.7mm outer diameter, 1.25mm wall thickness and 7m long stainless steel horizontal pipe with liquid nitrogen (LN2). The pipe is vacuum insulated during the experiment to minimize the heat leak from room temperature and to enable one to numerically simulate the process easily. The temperature and the pressure profiles of the chill-down line are obtained at the location which is 5.5m in a distance from the pipe inlet. The mass flux range is approximately from 19kg/m2s to 49kg/m2s, which corresponds to the Reynolds numbers range from 1469 to 5240. The transient histories of temperature, pressure and mass flow rate during the line chill-down process are monitored, and the heat transfer coefficient and the heat flux are computed by an inverse problem solving method. The amplitude of the pressure oscillation and the oscillating period become larger and longer at higher pressure conditions. In the low mass flux conditions, the critical heat flux in horizontal pipes is not sensitive to mass flux, and is higher than that in vertical pipes. Kutateladze’s correlation with the constant coefficient, B=0.029, well matches the experimental data in the current work. In nucleate flow boiling regime, heat transfer coefficient, h, is proportional to (q″)n, and n is equal to 0.7.
thermodynamics,physics, applied