Picometer-stable hexagonal optical bench to verify LISA phase extraction linearity and precision

Thomas S. Schwarze,Germán Fernández Barranco,Daniel Penkert,Marina Kaufer,Oliver Gerberding,Gerhard Heinzel
DOI: https://doi.org/10.1103/PhysRevLett.122.081104
2019-04-17
Abstract:The Laser Interferometer Space Antenna (LISA) and its metrology chain have to fulfill stringent performance requirements to enable the space-based detection of gravitational waves. This implies the necessity of performance verification methods. In particular, the extraction of the interferometric phase, implemented by a phasemeter, needs to be probed for linearity and phase noise contributions. This Letter reports on a hexagonal quasimonolithic optical bench implementing a three-signal test for this purpose. Its characterization as sufficiently stable down to picometer levels is presented as well as its usage for a benchmark phasemeter performance measurement under LISA conditions. These results make it a candidate for the core of a LISA metrology verification facility.
Instrumentation and Methods for Astrophysics,Instrumentation and Detectors,Optics
What problem does this paper attempt to address?
The paper attempts to address the issue of verifying the linearity and accuracy of the LISA (Laser Interferometer Space Antenna) phasemeter in extracting interferometric phases. Specifically, the paper focuses on the following points: 1. **Linearity**: The phasemeter needs to maintain linearity over a high dynamic range to ensure the extraction of critical displacement information from strong laser frequency noise. 2. **Phase Noise**: The phasemeter needs to maintain low phase noise in the low-frequency band (especially below 3 mHz) to meet LISA's phase extraction requirements. To achieve this goal, the authors designed and implemented a hexagonal quasi-monolithic optical platform for performing a three-signal test. This testing method can reveal noise sources that are undetected in traditional split tests and can verify the linearity and accuracy of the phasemeter. ### Main Contributions - **Stability**: The optical platform exhibits sufficient stability at the picometer level, suitable for performance verification of the LISA phasemeter. - **Three-Signal Test**: Through the three-signal test, the authors can verify the phasemeter's performance under LISA conditions, including high dynamic range and different heterodyne frequencies. - **Benchmark Testing**: Experimental results show that the optical platform can serve as a core part of the LISA metrology chain verification facility for future iterations and engineering model tests. ### Experimental Setup - **Laser Preparation**: Three 1064 nm lasers are used to generate initial signals, with frequencies locked through digital control loops to produce the required heterodyne frequencies. - **Phasemeter**: A digital phase-locked loop (DPLL) based on parallel ADC channels and FPGA is used to extract the phase. - **Optical Platform**: The hexagonal quasi-monolithic optical platform, through stable design and material selection (such as Zerodur substrates and fused silica beam splitters), ensures high stability. ### Results - **Testing Under Low Noise Conditions**: Under low heterodyne frequency and input phase noise conditions, the performance of the three-signal combination meets LISA requirements. - **Testing Under LISA-like Conditions**: In tests simulating actual LISA operating conditions, the phasemeter meets requirements in most frequency bands but shows some deviation in the 0.4-20 mHz range. - **Long-Term Testing**: Long-term tests show that the phasemeter maintains good performance under dynamic heterodyne frequencies, though low-frequency drift slightly increases. ### Discussion and Conclusion - **Platform Stability**: The hexagonal optical platform exhibits sufficient stability at the picometer level, supporting the verification of the LISA phasemeter's linearity and accuracy. - **Main Noise Sources**: The photoreceiver is one of the main noise sources, but further optimization can reduce noise levels. - **Future Work**: Plans include further reducing the noise floor of the test platform, particularly through optimization of polarization and photoreceivers. Overall, the paper demonstrates the effectiveness and potential of the hexagonal optical platform in verifying the performance of the LISA phasemeter, providing important technical support for future LISA missions.