Abstract:A potential background for the SuperCDMS SNOLAB dark matter experiment is from radon daughters that have plated out onto detector surfaces. To reach desired backgrounds, understanding plate-out rates during detector fabrication as well as mitigating radon in surrounding air is critical. A radon mitigated cleanroom planned at SNOLAB builds upon a system commissioned at the South Dakota School of Mines & Technology (SD Mines). The ultra-low radon cleanroom at SD Mines has air supplied by a vacuum-swing-adsorption radon mitigation system that has achieved $>$1000$\times$ reduction for a cleanroom activity consistent with zero and $<0.067\,$Bq$\,$m$^{-3}$ at 90% confidence. Our simulation of this system, validated against calibration data, provides opportunity for increased understanding and optimization for this and future systems.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to reduce the background noise caused by radon and its daughters in the SuperCDMS SNOLAB dark matter experiment. Specifically, the paper focuses on how to reduce the background events caused by the deposition of radon daughters on the detector surface by reducing the radon concentration in the clean room. These background events may have a significant impact on the detection sensitivity of low - mass dark matter. ### Specific description of the problem 1. **Background sources**: - The radioactive daughters of radon (such as \(^{210}\text{Pb}\) and the recoil \(^{206}\text{Pb}\) nucleus produced by the α - decay of \(^{210}\text{Po}\)) will be deposited on the detector surface and become the main low - energy background sources. - These background events pose significant challenges to experiments such as XMASS, SuperCDMS Soudan, EDELWEISS, and are still the main surface background sources for EDELWEISS - III. 2. **Requirements of the SuperCDMS SNOLAB experiment**: - The SuperCDMS SNOLAB experiment uses germanium and silicon detectors to search for dark matter interactions. - Although the iZIP detector can effectively exclude surface events when the energy is higher than 8 keV, at lower energies, this exclusion effect will be weakened, resulting in the radon daughter background may be dominant. - For high - voltage (HV) detectors, when the energy is lower than about 0.5 keV, the event exclusion based on the phonon sensor signal size becomes ineffective, so the radon daughter surface background is expected to exceed the background background when the \(^{210}\text{Pb}\) concentration exceeds 50 nBq cm\(^{-2}\). 3. **Challenges during the assembly process**: - During the underground assembly process at SNOLAB, if no measures are taken, the deposition of radon daughters may dominate the expected background. It is estimated that the assembly time is about 150 hours and the average radon concentration is 130 Bq m\(^{-3}\), which will result in a \(^{210}\text{Pb}\) deposition of about 70 nBq cm\(^{-2}\). - In order to make this deposition rate negligible, the goal of SuperCDMS SNOLAB is to achieve a radon concentration of < 0.1 Bq m\(^{-3}\) in the underground assembly clean room. ### Solutions The paper proposes an ultra - low - radon clean - room solution based on the Vacuum Swing Adsorption (VSA) system, which has been verified at the South Dakota School of Mines and Technology (SD Mines). The system reduces the radon concentration in the following ways: - **VSA system**: Alternately filter and regenerate through two or more monthly columns to ensure a continuous supply of low - radon air. - **Improved design**: Adopt the "slow - filling method" to reduce the number of valves, prevent the introduction of radon before the new regenerated column is used, and maintain mechanical stability. - **Simulation and optimization**: Predict the system performance through simulation, optimize the operating parameters, and further improve the radon removal efficiency. In summary, this paper aims to reduce the radon daughter background in the SuperCDMS SNOLAB experiment by developing and optimizing the ultra - low - radon clean - room system, thereby improving the sensitivity of low - mass dark matter detection.