Construction and Measurements of an Improved Vacuum-Swing-Adsorption Radon-Mitigation System

J. Street,R. Bunker,C. Dunagan,X. Loose,R.W. Schnee,M. Stark,K. Sundarnath,D. Tronstad
DOI: https://doi.org/10.1063/1.4928027
2015-06-02
Abstract:In order to reduce backgrounds from radon-daughter plate-out onto detector surfaces, an ultra-low-radon cleanroom is being commissioned at the South Dakota School of Mines and Technology. An improved vacuum-swing-adsorption radon mitigation system and cleanroom build upon a previous design implemented at Syracuse University that achieved radon levels of $\sim$0.2$\,$Bq$\,$m$^{-3}$. This improved system will employ a better pump and larger carbon beds feeding a redesigned cleanroom with an internal HVAC unit and aged water for humidification. With the rebuilt (original) radon mitigation system, the new low-radon cleanroom has already achieved a $>$$\,$300$\times$ reduction from an input activity of $58.6\pm0.7$$\,$Bq$\,$m$^{-3}$ to a cleanroom activity of $0.13\pm0.06$$\,$Bq$\,$m$^{-3}$.
Instrumentation and Detectors,High Energy Physics - Experiment