The Radon Monitoring System in Daya Bay Reactor Neutrino Experiment

M. C. Chu,K. K. Kwan,M. W. Kwok,T. Kwok,J. K. C. Leung,K. Y. Leung,Y. C. Lin,K. B. Luk,C. S. J. Pun
DOI: https://doi.org/10.1016/j.nima.2015.11.093
2016-01-19
Abstract:We developed a highly sensitive, reliable and portable automatic system (H$^{3}$) to monitor the radon concentration of the underground experimental halls of the Daya Bay Reactor Neutrino Experiment. H$^{3}$ is able to measure radon concentration with a statistical error less than 10\% in a 1-hour measurement of dehumidified air (R.H. 5\% at 25$^{\circ}$C) with radon concentration as low as 50 Bq/m$^{3}$. This is achieved by using a large radon progeny collection chamber, semiconductor $\alpha$-particle detector with high energy resolution, improved electronics and software. The integrated radon monitoring system is highly customizable to operate in different run modes at scheduled times and can be controlled remotely to sample radon in ambient air or in water from the water pools where the antineutrino detectors are being housed. The radon monitoring system has been running in the three experimental halls of the Daya Bay Reactor Neutrino Experiment since November 2013.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?
The paper attempts to address the issue of monitoring radon concentration in the underground experimental halls of the Daya Bay Reactor Neutrino Experiment. Specifically, the paper introduces a highly sensitive, reliable, and portable automated system (H3) developed for measuring radon concentration in the underground experimental halls. The H3 system is capable of measuring radon as low as 50 Bq/m³ in dry air (relative humidity 5%, temperature 25°C) within 1 hour, with a statistical error of less than 10%. This goal is achieved through the use of a large radon progeny collection chamber, a high-energy resolution semiconductor α-particle detector, and improved electronics and software. Additionally, the paper discusses the customized operation modes of the H3 system, which can operate in different modes at scheduled times and can remotely control the sampling of air or water in the pool. The system has been in operation in the three experimental halls of the Daya Bay Reactor Neutrino Experiment since November 2013. The main issues include: 1. **Background Suppression**: In the underground environment, α-particles produced by radon and its progeny can become background noise for the experiment, affecting the results. Therefore, effective monitoring and control of radon concentration are required. 2. **Real-time Monitoring**: Continuous monitoring of radon concentration in the air and water around the pool in the experimental halls is needed to ensure the stability and safety of the experimental environment. 3. **High Sensitivity and Low Error**: The system is required to have high sensitivity and low statistical error at low radon concentrations to accurately measure radon concentration. 4. **Portability and Remote Operation**: The system needs to be portable and capable of remote operation to facilitate measurements under different locations and conditions. By addressing these issues, the H3 system provides important technical support for the Daya Bay Reactor Neutrino Experiment, helping to improve the accuracy and reliability of the experiment.