Radon Removal Commissioning of the PandaX-4T Cryogenic Distillation System

Xiangyi Cui,Zhou Wang,Jiafu Li,Shuaijie Li,Lin Si,Yonglin Ju,Wenbo Ma,Jianglai Liu,Li Zhao,Xiangdong Ji,Rui Yan,Haidong Sha,Peiyao Huang,Xiuli Wang,Huaxuan Liu
2024-04-19
Abstract:The PandaX-4T distillation system, designed for the removal of krypton and radon from xenon, is evaluated for its radon removal efficiency using a $^{222}$Rn source during the online distillation process. The PandaX-4T dark matter detector is employed to monitor the temporal evolution of radon activity. To determine the radon reduction factor, the experimental data of radon atoms introduced into and bypassed the distillation system is compared. The results indicate that the PandaX-4T distillation system achieves a radon reduction factor exceeding 190 at the flow rate of 10 slpm and the reflux ratio of 1.44. Gas-only online distillation process of a flow rate of 20 slpm is also conducted without observing significant reduction of radon levels in the detector. This observation suggests that the migration flow of radon atoms from the liquid phase to the gas phase is limited, and the flow rate of gas circulation and duration of the process are insignificant compared to the total xenon mass of 5.6 tons in the detector. This study provides the experimental data to support the efficient removal of radon at $\sim$Bq level using the PandaX-4T distillation system, which is the prerequisite of the radon background control in the detector. The further operation with higher flow rate will be applied for the upcoming science run in PandaX-4T.
Instrumentation and Detectors
What problem does this paper attempt to address?
This paper focuses on the removal of radon in the PandaX-4T dark matter detector. The purpose of the experiment is to evaluate the performance of the PandaX-4T distillation system designed for the removal of krypton and radon in xenon gas, especially its ability to remove radon. The study determines the radon reduction factor through the monitoring of time evolution using a 222Rn source during the online distillation process. The results show that the system achieves a radon reduction factor of over 190 at a flow rate of 10 slpm and a reflux ratio of 1.44. However, no significant reduction in radon levels was observed during the online distillation process for the 20 slpm gas, indicating limited migration of radon atoms from the liquid phase to the gas phase. The paper also discusses the distillation process under different operating conditions, including initial injection, self-circulation, second injection, and gas-only online distillation. These studies provide data support for controlling background radiation in the detector, especially for controlling radon background at around Bq levels. Future plans involve conducting further operations at higher flow rates.