A new MicroTCA-based waveform digitizer for the Muon g-2 experiment

David A. Sweigart
DOI: https://doi.org/10.48550/arXiv.1612.05145
2016-12-16
Abstract:We present the design of a new $\mu$TCA-based waveform digitizer, which will be deployed in the Muon g-2 experiment at Fermilab and will allow our pileup identification requirement to be met. This digitizer features five independent channels, each with 12-bit, 800-MSPS digitization and a 1-Gbit memory buffer. The data storage and readout along with configuration are handled by six Xilinx Kintex-7 FPGAs. In addition, the digitizer is equipped with a mezzanine card for analog signal conditioning prior to digitization, further widening its range of possible applications. The performance results of this design are also presented, highlighting its $0.51 \pm 0.13$ mV intrinsic noise level and $< 22$ ps intrinsic timing resolution between channels. We believe that its performance, together with its flexible design, could be of interest to future experiments in search of a cost-effective waveform digitizer.
Instrumentation and Detectors
What problem does this paper attempt to address?
This paper aims to design and implement a new waveform digitizer based on MicroTCA (μTCA) technology, which is specifically used in the Muon g - 2 experiment at Fermilab. The main goal of this work is to meet the overlapping event (pileup) identification requirements in the Muon g - 2 experiment and reduce the measurement deviation caused by high - energy positron multiple events by improving the performance of the waveform digitizer. Specifically, the paper describes the following points: 1. **Experimental background and challenges**: The goal of the Muon g - 2 experiment is to measure the anomalous magnetic moment (\(a_μ\)) of the muon with a precision of 140 ppb, which is a significant improvement over the results of the previous BNL E821 experiment. In the experiment, charged muons rotate in a storage ring with a uniform magnetic field, and the positrons produced by their decay are detected by 24 electromagnetic calorimeters. To achieve the required precision, the experiment plans to increase the number of muons in the storage ring, which will lead to a significant increase in the number of overlapping events and thus affect the measurement precision. Therefore, a method that can effectively separate these overlapping events is needed. 2. **Technical solution**: To solve the above problems, the author designed a waveform digitizer with five independent channels, each channel having a 12 - bit, 800 MSPS (million samples per second) digitization capability and a 1 - gigabit memory buffer. This design is a significant improvement over previous systems (8 - bit, 400 MSPS) and can better identify positron signals that are close in time and reduce the impact of overlapping events. In addition, the digitizer is equipped with an analog front - end processing card for pre - processing the signal before digitization, further expanding its application range. 3. **Performance evaluation**: The paper also reports the performance test results of this digitizer, including its inherent noise level of 0.51±0.13 mV and a time resolution between channels of less than 22 picoseconds (ps). These performance indicators show that this digitizer can not only meet the requirements of the Muon g - 2 experiment, but also its flexibility and cost - effectiveness make it an ideal choice for future similar experiments. In conclusion, through detailed design and performance analysis, this paper presents an efficient and reliable waveform digitization solution, which is especially suitable for high - energy physics experiments that require precise measurement and processing of complex signals.