Charge Distribution Dependency on Gap Thickness of CMS Endcap RPC

Sung K. Park,Min Ho Kang,Kyongsei Lee
DOI: https://doi.org/10.1088/1748-0221/11/11/C11034
2016-05-07
Abstract:We report a systematic study of charge distribution dependency of CMS Resistive Plate Chamber (RPC) on gap thickness. Prototypes of double-gap RPCs with six different gap thickness ranging from from 1.0 to 2.0 mm in 0.2-mm steps have been built with 2-mm-thick phenolic high-pressure-laminated plates. The efficiencies of the six gaps are measured as a function of the effective high voltages. We report that the strength of the electric fields of the gap is decreased as the gap thickness is increased. The distributions of charges in six gaps are measured. The space charge effect is seen in the charge distribution at the higher voltages. The logistic function is used to fit the charge distribution data. Smaller charges can be produced within smaller gas gap. But the digitization threshold should be also lowered to utilize these smaller charges.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?