Neuronal Multi Unit Activity Processing with Metal Oxide Memristive Devices

Caterina Sbandati,Xiongfei Jiang,Deepika Yadav,Spyros Stathopoulos,Dana Cohen,Alex Serb,Shiwei Wang,Themis Prodromakis
DOI: https://doi.org/10.1002/aelm.202400638
IF: 6.2
2024-11-07
Advanced Electronic Materials
Abstract:An RRAM‐based platform for detecting behavioral patterns from in‐vivo multi‐unit activity envelope (eMUA). The platform tested on two types of metal‐oxide RRAM achieved over 95% detection sensitivity. The RRAM processing shows benefits in integrated front‐end design, as it enables for down‐sampling of the input, reducing full‐chain power consumption below 1 μW and making it suitable for low‐power brain‐machine interfaces. Intra‐cortical brain‐machine interfaces (BMIs), able to decode neural activity in real‐time, represent a revolutionary opportunity for treating medical conditions. However, traditional systems focusing on single‐neuron spike detection require high processing rates and power, hindering the up‐scaling for neurons‐population monitoring in clinical application. An intriguing proposition is the memristive integrating sensor (MIS) approach, which uses resistive RAM (RRAM) for threshold‐based neural activity detection. MIS leverages analogue multi‐state switching properties of metal‐oxide RRAM to compress neural inputs by encoding above‐threshold events in resistance displacement, facilitating efficient data down‐sampling in the post‐processing, enabling low‐power, high‐channel systems. Initially tested on spikes and local field potentials, here MIS is adapted to process multi‐unit activity envelope (eMUA)—the envelope of entire spiking activity—which has recently been proposed as crucial input for real‐time neuro‐prosthetic control. Prior necessary modifications to the MIS for effective operation, this adaptation achieved over 95% sensitivity across two types of metal‐oxide devices: Pt/TiOx/Pt and TiN/HfOx/TiN, proving its platform‐agnostic capabilities. Furthermore, towards the integration of MIS with silicon chips, it is shown that it can reduce total system power consumption to below 1 μW, as RRAM encoding stage relaxes the signal preservation and noise requirements that challenge traditional complementary metal‐oxide‐semiconductor (CMOS) front‐ends. This eMUA‐MIS adaptation offers a viable pathway for developing more scalable and efficient BMIs for clinical use.
materials science, multidisciplinary,physics, applied,nanoscience & nanotechnology
What problem does this paper attempt to address?