Simulation of LiCAS Error Propagation

G. Grzelak,A. Reichold,J. Dale,M. Dawson,J. Green,Y. Han,M. Jones,G. Moss,B. Ottewell,R. Wastie,D. Kämptner,J. Prenting,M. Schlösser
DOI: https://doi.org/10.48550/arXiv.0709.2012
2007-09-13
Abstract:Linear Collider Alignment and Survey (LiCAS) R&D group is proposing a novel automated metrology instrument dedicated to align and monitor the mechanical stability of a future linear high energy e+e- collider. LiCAS uses Laser Straightness Monitors (LSM) and Frequency Scanning Interferometry (FSI) for straightness and absolute distance measurements, respectively. This paper presents detailed simulations of a LiCAS system operating inside a Rapid Tunnel Reference Surveyor (RTRS train). With the proposed design it is feasible to achieve the required vertical accuracy of the order of 200 micons over 600 m tunnel sections meeting the specification for the TESLA collider.
Instrumentation and Detectors,Accelerator Physics