Beam-Based Measurements of Long Range Transverse Wakefields in CLIC Main Linac Accelerating Structure

Hao Zha,E. Adli,Giovanni De Michele,Alexej Grudiev,A. Latina,N. Lipkowitz,Daniel Schulte,Anastasiya Solodko,Walter Wuensch,G. Yocky
DOI: https://doi.org/10.18429/jacow-ipac2015-tupty056
2015-01-01
Abstract:The baseline design of CLIC (Compact Linear Collider) uses X-band accelerating structures in the main linacs. Every accelerating structure cell has four waveguides, terminated with individual RF loads, to damp the unwanted long-range transverse wakefields in order to maintain beam stability in multi-bunch operation. In order to experimentally verify the calculated suppression of wakefields, a prototype structure has been built and installed in FACET test facility at SLAC. The results of the measurements of the wakefields in the prototype structure, by means of positron and electron bunches, are presented.