Efficient extraction of a collimated ultra-cold neutron beam using diffusive channels

P. Schmidt-Wellenburg,J. Barnard,P. Geltenbort,V.V. Nesvizhevsky,C. Plonka,T. Soldner,O. Zimmer
DOI: https://doi.org/10.1016/j.nima.2007.03.032
2007-03-07
Abstract:We present a first experimental demonstration of a new method to extract a well-collimated beam of ultra-cold neutrons (UCN) from a storage vessel. Neutrons with too large divergence are not removed from the beam by an absorbing collimation, but a diffuse or semidiffuse channel with high Fermi potential reflects them back into the vessel. This avoids unnecessary losses and keeps the storage time high, which may be beneficial when the vessel is part of a UCN source with long buildup time of a high UCN density.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to efficiently extract a collimated beam of ultra - cold neutrons (UCN) from a storage container while minimizing unnecessary losses and maintaining a relatively long storage time. Specifically, the authors propose a new method. Instead of removing the neutrons with large divergence angles by using an absorption collimator, they use rough or semi - rough channels with high Fermi potential to reflect these neutrons back into the storage container. ### Background and Problem Description In many next - generation UCN sources, cold neutrons are usually converted into ultra - cold neutrons (EUCN ≤ 250 neV) through solid deuterium or superfluid helium. These UCNs will accumulate in a storage container to form a high - density UCN, and be continuously or periodically extracted from it according to experimental requirements. The saturated UCN density in the storage container is given by the following formula: \[ \rho_{\text{UCN}} = P \tau_{\text{tot}} \] where \( P \) is the production rate per unit volume, and \( \tau_{\text{tot}} \) is the total storage time of the container. Any aperture will reduce the storage time \( \tau_{\text{tot}} \), thereby reducing the maximum density and extraction flux. If the experiment only requires a UCN beam with a narrow divergence angle, it is advantageous to avoid unnecessary neutron losses. ### Proposed Method The authors propose a new method, that is, using rough - surfaced channels with high Fermi potential to reflect neutrons with large divergence angles. This method can avoid unnecessary losses and maintain a relatively long storage time. Specifically, they designed two types of channels: a completely rough channel (double - diffusion channel, dd) and a half - rough - half - mirror - surfaced channel (semi - diffusion channel, sd). These two types of channels can effectively reflect neutrons and make them return to the storage container, unless they decay. ### Experimental Verification To verify this new method, the authors carried out experiments on the ultra - cold neutron device PF2 at the Institut Laue Langevin (ILL) in Grenoble, France. They measured the storage time and reflectivity under different configurations and reached the following conclusions: 1. **Reflectivity**: For the 100 µm - high semi - diffusion channel, the reflectivity reached more than 80%. 2. **Storage Time**: The storage lifetime of the semi - diffusion configuration has increased compared to the mirror configuration, especially when the height is 100 µm, the reflectivity is as high as 80% and the storage time is hardly reduced. ### Conclusion This research shows that a collimated ultra - cold neutron beam can be continuously extracted from a storage container through semi - diffusion or completely rough channels without significantly reducing its storage time. This new method has broad application prospects in future experiments.