Abstract:Oil and gas are still largely transported by long-distance pipelines. In this study, we aimed to examine the impact of the high-voltage DC transmission grounding electrode on long-distance pipelines' cathodic protection system nearby. The writer built the interference model of the DC transmission grounding electrode on the pipeline using COMSOL Multiphysics based on the parameters of the actual project and considering the cathodic protection system within and then tested the model using...
What problem does this paper attempt to address?
This paper aims to study the influence of high - voltage direct - current (HVDC) transmission grounding electrodes on the cathodic protection system of long - distance oil pipelines. Specifically, the author analyzes the current density distribution and the cathodic protection potential distribution rules under different conditions by establishing an interference model between the HVDC transmission grounding electrode and the pipeline and using COMSOL Multiphysics software for simulation calculation. These conditions include the grounding electrode's earth - entering current, the distance between the grounding electrode and the pipeline, soil conductivity, and the surface resistance of the pipeline coating.
### Research Background
- **High - voltage direct - current (HVDC) transmission system**: The HVDC transmission system has gradually become the mainstream technology in power system transmission due to its long - distance transmission and high power grid stability.
- **Long - distance oil pipeline**: Long - distance oil pipelines are still the main means of transporting oil and natural gas. Due to factors such as terrain and soil characteristics, there are similarities in the route selection of HVDC transmission lines and oil pipelines, resulting in the possible occurrence of cross - parallel phenomena during the construction of the two, thus causing inevitable interference to the pipeline in the HVDC area.
- **Interference factors**: The influence of HVDC transmission lines on nearby buried metal pipelines is mainly divided into two aspects: the influence of the DC electric field and the influence of the DC current. Among them, the influence of the DC current is caused by the grounding electrode of the HVDC transmission line and the return current passing through the surrounding land and the pipeline, which will cause a potential difference in the metal pipeline and then cause electrochemical corrosion.
### Research Methods
- **Model establishment**: Based on the parameters of the actual project, the author used COMSOL Multiphysics software to establish an interference model of the HVDC transmission grounding electrode on the pipeline and considered the cathodic protection system on the pipeline.
- **Simulation calculation**: By simulating and calculating the grounding electrode's earth - entering current, the distance between the grounding electrode and the pipeline, soil conductivity, and the surface resistance of the pipeline coating under different conditions, the current density distribution and the cathodic protection potential distribution rules in the pipeline were obtained.
### Main Results
- **Current density distribution**: The simulation results show that the lower the soil conductivity, the higher the current density in the pipeline. When the soil conductivity is 0.005 S/m, the maximum current density inside the pipeline reaches 160 A/m².
- **Cathodic protection potential distribution**: Lower soil conductivity will lead to a significant shift in the cathodic protection potential. For example, when the soil conductivity is 0.001 S/m, the cathodic protection potential of the pipeline within a 10 - kilometer range from the nearest grounding electrode rapidly shifts to 24 V.
- **Influence of the grounding electrode's earth - entering current**: As the grounding electrode's earth - entering current increases, the current density in the pipeline also increases. When the grounding electrode's earth - entering current is 5000 A, the maximum current density in the pipeline reaches 225 A/m². In the bipolar grounding mode, when the grounding electrode's earth - entering current is 50 A, the interference to the pipeline can be ignored.
- **Influence of the surface resistance of the pipeline coating**: Increasing the surface resistance of the pipeline coating can reduce the current density in the pipeline. When the surface resistance of the coating exceeds 5×10⁴ Ω·m², the current density in the pipeline is small and stable. Higher surface resistance of the coating can improve the anti - interference ability and anti - corrosion ability of the pipeline.
### Conclusion
This research, verified by simulation and experimental data, reveals the influence mechanism of the HVDC transmission grounding electrode on the cathodic protection system of long - distance oil pipelines. The research results provide important theoretical basis and technical support for evaluating and preventing the interference of the HVDC transmission system on pipelines.