Neutron sensitivity and uncertainty analysis of rhodium self-powered neutron detectors for reactor monitoring in HPR1000

Xiong Wu,Jieqiong Jiang,Tingyu Wu,Shijie Luo
DOI: https://doi.org/10.1016/j.pnucene.2024.105110
IF: 2.461
2024-02-17
Progress in Nuclear Energy
Abstract:The advanced Gen-III pressurized water reactor (PWR) HPR1000 utilizes rhodium self-powered neutron detectors (SPNDs) for reactor monitoring to guarantee safety operation. However, the neutronic characteristics of rhodium SPND result in its sensitivity being dependent on both thermal neutrons and epithermal neutrons and thereby introducing uncertainty. In this study, a computational model based on the Monte Carlo (MC) method is presented for the neutron sensitivity of rhodium SPND, and the calculated values are compared with experimental measurements to prove its effectiveness. Then several fuel assemblies at symmetrical locations in the HPR1000 are selected to quantifiably evaluate the sensitivity uncertainties of rhodium SPNDs. The calculation methods and evaluation results have successfully provided guidance for industrial applications in the HPR1000 and could be a valuable reference for other reactors.
nuclear science & technology
What problem does this paper attempt to address?