Cryopanel and fast closing valve system for ISOL beam operation

Jongwon Kim
DOI: https://doi.org/10.1016/j.nimb.2024.165321
2024-03-17
Abstract:We designed a cryopanel system based on Molflow+ simulation and constructed for installation in a beam line of 70 MeV H - cyclotron to adsorb back streaming radioactive molecules from ISOL target. Since the target assembly is not hermetically sealed, a target leak can occur especially during high-power beam operation. The cryopanel surrounds the beam path to enhance adsorption efficiency and can be kept at temperature as low as 10 K. A beam test carried out at a current of ∼1 μA showed the panel temperature is not affected by beam pass. The vacuum in the panel region improves to better than 1 × 10 -7 mbar so residual gas spectrum has a low background in detection of target leak. As part of the safety system against target damage, a fast closing valve is installed. These safety systems have been tested as essential components for radiation protection in ISOL operation.
physics, nuclear, atomic, molecular & chemical,nuclear science & technology,instruments & instrumentation
What problem does this paper attempt to address?