The cyclotron gas stopper project at the NSCL

C. Guenaut,G. Bollen,S. Chouhan,F. Marti,D.J. Morrissey,D. Lawton,J. Ottarson,G.K.Pang,S. Schwarz,B.M. Sherrill,M.Wada,A.F. Zeller
DOI: https://doi.org/10.1007/s10751-007-9539-y
2007-03-26
Abstract:Gas stopping is becoming the method of choice for converting beams of rare isotopes obtained via projectile fragmentation and in-flight separation into low-energy beams. These beams allow ISOL-type experiments, such as mass measurements with traps or laser spectroscopy, to be performed with projectile fragmentation products. Current gas stopper systems for high-energy beams are based on linear gas cells filled with 0.1-1 bar of helium. While already used successfully for experiments, it was found that space charge effects induced by the ionization of the helium atoms during the stopping process pose a limit on the maximum beam rate that can be used. Furthermore, the extraction time of stopped ions from these devices can exceed 100 ms causing substantial decay losses for very short-lived isotopes. To avoid these limitations, a new type of gas stopper is being developed at the NSCL/MSU. The new system is based on a cyclotron-type magnet with a stopping chamber filled with Helium buffer gas at low pressure. RF-guiding techniques are used to extract the ions. The space charge effects are considerably reduced by the large volume and due to a separation between the stopping region and the region of highest ionization. Cyclotron gas stopper systems of different sizes and with different magnetic field strengths and field shapes are presently investigated.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to efficiently convert rare - isotope beams obtained through projectile fragmentation and in - flight separation into low - energy beams in high - energy beam currents for ISOL - type experiments, such as mass measurement or laser spectroscopy research. Although the current gas stopper systems have been successfully applied in experiments, they have two main limitations: 1. **Space - charge effect**: During the stopping process, the space - charge effect caused by the ionization of helium atoms limits the maximum beam current rate that can be used. 2. **Excessively long extraction time**: The time to extract the stopped ions from these devices may exceed 100 milliseconds, which will lead to significant attenuation losses of very short - lived isotopes. To overcome these limitations, researchers are developing a new gas stopper - the Cyclotron Gas Stopper. This new - type stopper is based on a cyclotron - type magnet, the stopping chamber is filled with low - pressure helium buffer gas, and ions are extracted using RF guiding technology. By increasing the volume and separating the stopping area from the area with the highest ionization, this design significantly reduces the space - charge effect. In addition, the Cyclotron Gas Stopper also aims to achieve the following goals: - **Shorten the extraction time**: To minimize attenuation losses, the extraction time should match or be shorter than that of ions with the shortest half - life, and the ideal extraction time should be 10 milliseconds or less. - **Efficient stopping and extraction at high beam - current intensities**: Next - generation facilities will provide rare - isotope beam - current intensities of up to \(10^9\) ions/second and need to efficiently handle ionization - rate densities of about \(10^{11}\) IP/cm³/s. - **Applicable to all fragment beams**: To be versatile, the gas stopper needs to be able to handle isotope beams with different charges \(Z\) and neutron - proton ratios. Through these improvements, the Cyclotron Gas Stopper is expected to meet the needs of future rare - isotope research.