A Model for Inverter Loss Considering Output Current Ripple

Guo-zhu Chen,Hongyi Lin,Daoyi Huang,Jiasheng Xu
DOI: https://doi.org/10.1109/ICPRE55555.2022.9960706
2022-09-23
Abstract:In this paper, an inverter loss model is proposed, and the two-level topology is taken as an example to analyze and illustrate this model. Considering the high frequency ripple of the inverter output current at switching times, when the output current crosses zero, the power device is in the soft switching state. Two power devices on a bridge arm successively appear in the soft switching-on state, which does not exist in the traditional average current loss analysis. This paper focuses on the analysis of the switching loss in this state to improve the accuracy of the loss model. The converting process of the one-phase bridge arm is analyzed in this paper, and then the loss of each stage of the power device is modeled based on it. The loss calculation method proposed in this paper is verified by the grid-connected experiment of a SiC-380V /50kVar inverter. The experimental results show that the loss model proposed in this paper improves the accuracy of the traditional model. The loss model presented in this paper can also be extended to other high frequency power electronic inverter topologies, such as type I three-level and type T three-level.
Engineering
What problem does this paper attempt to address?