Research on Ultra High Frequency Induction Heating Power Supply Inverter Load Topology

岳金伟,陈辉明,王正仕
DOI: https://doi.org/10.3969/j.issn.1001-4551.2010.06.018
2010-01-01
Abstract:Aiming at the troublesome of the switching loss and induction heating load variation in ultra high frequency induction heating power supply inverter,a novel bi-switching ultra high frequency resonant inverter was introduced.In the circuit,the trail inductive and capacitive parasitic parameters can be absorbed.The zero-voltage turn-off and the zero-voltage,zero-current turn-on were realized,in which the switching loss of the switch tube can be reduced greatly.The working conditions of the topology in inductive,resistive and capacitive load were analyzed.At the same time,the scope and conditions of the zero-voltage soft-switching in four kinds of classical inverter load were researched.Simulation and experimental results operating around 1 MHz frequency were presented.The results indicate that LLC inverter load topology is the most suitable one for this inverter.
What problem does this paper attempt to address?