Control System Design for the LIGO Pre-stabilized Laser

R. Abbott,P. King
DOI: https://doi.org/10.48550/arXiv.physics/0111155
2001-11-21
Abstract:To meet the strain sensitivity requirements [1], [2] of the Laser Interferometer Gravitational Wave Observatory (LIGO), the laser frequency and amplitude noise must initially be reduced by a factor of 1000 in the pre-stabilized portion of the interferometer [3]. A control system was implemented to provide laser noise suppression, data acquisition interfaces, diagnostics, and operator control inputs. This paper describes the VME-based analog and digital controls used in the LIGO Pre-stabilized Laser (PSL).
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in order to meet the strain sensitivity requirements of the Laser Interferometer Gravitational - wave Observatory (LIGO), the laser frequency and amplitude noise must be reduced by 1000 times in the pre - steady - state part. Specifically, LIGO needs to achieve extremely high sensitivity to detect weak gravitational - wave signals, and these signals may be masked by the noise of the laser itself. Therefore, the researchers designed and implemented a control system to suppress laser noise, provide data acquisition interfaces, diagnostic functions, and operator control inputs. ### Key Problem Analysis: 1. **Laser Noise Suppression**: - LIGO has strict requirements for laser frequency and amplitude noise. In order to achieve the required strain sensitivity, the laser frequency and amplitude noise must be reduced by 1000 times in the pre - steady - state part. - The specific requirement is that at a 25 MHz modulation frequency and an output optical power of 600 mW, the noise is close to the shot - noise limit. 2. **Frequency Stabilization**: - In order to be able to reasonably detect candidate gravitational - wave sources, the displacement sensitivity of the LIGO detector at 100 Hz must be better than \(10^{-19} \, \text{m}/\sqrt{\text{Hz}}\), which is equivalent to a frequency noise of \(10^{-7} \, \text{Hz}/\sqrt{\text{Hz}}\). - The paper describes in detail how to use three frequency actuators to stabilize the laser frequency: thermoelectric coolers (TEC), piezoelectric ceramics (PZT), and Pockels cells. Each actuator covers a different frequency range to ensure frequency stability across the entire frequency band. 3. **Intensity Stabilization**: - Laser photons will cause radiation pressure noise in the interferometer, and this noise will cause statistical movement of the mirror due to the different photon momenta. In order to minimize this effect, the laser intensity fluctuation must be stabilized to the level of \(10^{-8} \, \text{1}/\sqrt{\text{Hz}}\). - The intensity stabilization system adopts a double - loop topology structure. It monitors the light intensity before and after the mode cleaner through a photodetector and uses a current shunt to quickly adjust the current of the power amplifier pump diode. 4. **Data Acquisition and User Control**: - The system performs user control and interface interaction through the Experimental Physics and Industrial Control System (EPICS). Operators can remotely monitor the performance of the PSL and adjust the gains and settings of various servo loops. - The data acquisition system records and logs multiple signals. Fast signals are acquired at a rate of 16 kHz, and slow signals are acquired at a rate of 256 Hz. ### Summary: The main objective of this paper is to design and implement an efficient control system to ensure that the laser source of LIGO is stable enough in both frequency and intensity, thereby enhancing LIGO's ability to detect gravitational waves. Through detailed hardware design and control strategies, the researchers successfully reduced the laser noise by 1000 times, meeting LIGO's high - sensitivity requirements.