Laser Stabilization Controls for the ISAC Beam Polarizer

R. Nussbaumer,D. Dale,H. Hui,J. Richards,P. Levy
DOI: https://doi.org/10.48550/arXiv.physics/0111081
2001-11-10
Abstract:The ISAC polarized beam facility uses a Ti:Sapphire laser for producing spin-polarized beams of short-lived radioactive isotopes, initially 7Li. The laser power and spectral content must be tightly controlled and monitored. The control system to accomplish this task uses techniques that combine operator interface, data reduction, and closed loop automation. The laser stabilization application uses input data acquired from a spectrum analyzer, in the form of a waveform array repetitively acquired from a GPIB-interfaced oscilloscope. A Labview based operator interface allows the selection of features from within the waveform, which are then used as the basis for closed loop control, in concert with the existing EPICS control system software and related hardware. Part of the challenge stems from using input data which are subject to human interpretation and require distillation into a hard numeric format suitable for use in a control system.
Accelerator Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: how to enhance the stability of a Ti:Sapphire laser by developing and implementing an external control system to ensure that the ISAC polarized beam facility can produce highly polarized short - lived radioisotope beams, especially 7Li, for a long time. ### Specific problem description: 1. **Insufficient laser stability**: - The stability of the Ti:Sapphire laser is not sufficient to maintain the required degree of polarization over the long time (more than a few seconds) required by the experiment. - The fundamental frequency and spectral content of the laser need to be strictly controlled and monitored. 2. **Challenges in data extraction and processing**: - The waveform data obtained from the spectrum analyzer has jitter, resulting in frequency drift. - The data baseline value is unstable and contains noise, making feature extraction complicated. - It is necessary to convert human - interpreted data into a precise numerical format suitable for use by the control system. 3. **Requirement for real - time control**: - The control system needs to respond in real - time and adjust various parameters of the laser, such as the cavity length, etalon filter angle, etc. - The existing combination of Labview and EPICS software has limitations in high sampling rate and real - time performance, affecting the reliability and response speed of the system. ### Solution overview: - **Hardware control**: - Use a piezo - electric element to adjust the laser cavity length. - Use a servo motor to adjust the angle of the etalon filter. - **Software control**: - Developed a Labview - based operation interface for selecting waveform features and performing closed - loop control. - Combined with the EPICS control system to achieve automated control of the laser. - Obtain waveform data through a spectrum analyzer and a digital storage oscilloscope (DSO), and perform filtering, peak detection and tracking. ### Goals and achievements: - Achieved stable operation of the laser for several hours without human intervention, meeting the needs of polarized beam production. - Identified and solved several deficiencies in the existing system, providing directions for further improvement, such as increasing the bandwidth of the measurement and control system and using a more powerful real - time operating system to eliminate high - frequency noise. Through these measures, this paper shows how to significantly improve the stability and reliability of the Ti:Sapphire laser through advanced control techniques and data processing methods, thereby providing a guarantee for the efficient operation of the ISAC polarized beam facility.