Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport

Andy LaBella,Wei Zhao,Rick Lubinsky,Amir H Goldan
DOI: https://doi.org/10.1088/1361-6560/ab9373
IF: 3.5
2020-09-16
Physics in Medicine and Biology
Abstract:High spatial resolution PET relies on having excellent depth-of-interaction (DOI) resolution and small detector elements. Depth-encoding in PET modules has traditionally been performed using dual-ended readout. In recent years, researchers have explored the feasibility of replacing the second readout array with a light guide at the entrance layer that introduces intercrystal light sharing in order to reduce cost and and make depth-encoding modules more compact. However, single-ended readout depth-encoding modules have suboptimal and non-uniform crystal separation and DOI performance due to the random light sharing patterns of the uniform light guide, resulting in degraded peformance along the edges and corners of the detector arrays. In this paper, we introduce and characterize a segmented light guide composed of an array of prism mirrors which introduce deterministic intercrystal light sharing in single-ended readout PET detectors. We determined the expected spatial performance of our modules with our light guide using optical ray tracing Monte Carlo simulations. We demonstrate that having controlled, deterministic light sharing improves both DOI and crystal identification performance, enabling uniform spatial performance throughout the detector array. Designed specifically for high resolution PET, our prismatoid light guide array can be used to build cost-effective total-body and organ-dedicated PET systems with single-ended readout depth-encoding modules.
engineering, biomedical,radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?
This paper aims to solve the problem of spatial resolution in positron emission tomography (PET), especially to improve the depth - of - interaction (DOI) resolution and the performance of small detection elements. Specifically, the researchers explored a new segmented light - guide design, an array composed of a series of prisms, to achieve deterministic inter - crystal light sharing in single - end - readout PET detectors. Through optical ray - tracing Monte Carlo simulations, the researchers evaluated the spatial performance of this new type of light - guide module and demonstrated its potential in improving DOI and crystal - identification performance, thus achieving uniform spatial performance across the entire detector array. The key contributions of the paper are: 1. **Introduction of a new segmented light - guide**: A light - guide composed of a prism array can control and enhance the light sharing between crystals, thereby improving the accuracy of DOI and crystal identification. 2. **Optimization of edge and corner effects**: Through a special light - guide geometric design, the edge and corner effects existing in traditional uniform light - guides are eliminated, improving the uniformity of the entire detector array. 3. **Cost - effective design**: This design allows a 9:1 crystal - to - pixel coupling ratio while maintaining good crystal - identification performance, providing an economical and effective solution for the construction of high - resolution PET systems. In conclusion, this paper solves the key problems in single - end - readout depth - encoded PET modules by proposing an innovative light - guide design, providing new ideas for improving the spatial resolution and performance of PET imaging.