Control of electrochemical parameters for hydrogen permeation of CLF-1 steel
Fantao Meng,Long Wang,Zhihao Hong,Pinghuai Wang,Chunhai Liu,Zikai Liu,Qixiang Cao,Baoping Gong,Youzhi Wang,Long Zhang,Yuxiang Zhao
DOI: https://doi.org/10.1016/j.fusengdes.2024.114280
IF: 1.905
2024-03-02
Fusion Engineering and Design
Abstract:The electrochemical hydrogen permeation method is reliable for evaluating the intrinsic hydrogen permeation resistance due to its room-temperature operation. However, the control of electrochemical parameters for hydrogen permeation testing has rarely been reported. In this study, we discussed the effects of anode background current, cathode current density, and cycle times on the electrochemical permeation behavior of CLF-1 RAFM steel. Results show that the anode background current below 1μA can ensure the accuracy of the permeation test. There exists a diffusion delay for the first permeation loop of CLF-1 steel because of the hydrogen trap effect, which can be eliminated by annealing the steel at temperature of 740 °C for 2h. For the second and third permeation loops of CLF-1 steel, a sample with a high cathode current density tends to have a high permeation signal because of corrosion. Plating a protective nickel film can reduce the corrosion impacts for the hydrogen permeation test. The effects of hydrogen traps and corrosion on the permeation behavior were discussed in detail. Our study provides a promising approach for hydrogen permeation testing and hydrogen trap detection at room temperature.
nuclear science & technology