Excess sludge conditioning with ultrasound/ozone and its effect on the anaerobic anoxic oxic process in a municipal wastewater treatment plant

Hongyang Ren,Yan Wang,Zijing Wei,Puzhen Liu,Bing Wang
DOI: https://doi.org/10.1016/j.psep.2020.04.052
IF: 7.8
2020-08-01
Process Safety and Environmental Protection
Abstract:The sludge treatment of ultrasound-ozone was an promising way for small sewage plant.The ultrasound improved ozone mass transfer, promoting the excess sludge reduction.The reduction efficiency of ultrasound-ozone was reaching the maximum about 68.1%.The yield of excess sludge reduced by 51.3% in A/A/O under the optimized operation.Impact of ultrasonication and ozonation pre–treatment on the sewage sludge and ultrasonication–ozonation integrated with anaerobic anoxic oxic system were investigated. According to response surface methodology, the optimal conditions were determined for an ozone dosage of 0.14 g·O<sub>3</sub>/g·SS and an ultrasonic intensity of 1.61 W/mL, which corresponded to a maximum sludge reduction ratio of 68.1%. When the residence time of broken sludge was 30 min and the reflux ratio was 60%, the broken sludge returned to the anaerobic or anoxic zone had little effect on chemical oxygen demand and improved total phosphorus removal rate of the anaerobic anoxic oxic system effluent. The broFken sludge was returned to the anoxic zone, the removal rate of total nitrogen in the effluent of the anaerobic anoxic oxic system could be increased by 13.2%. The broken sludge backflow improved the sedimentation performance of the anaerobic anoxic oxic system sludge, which had little to do with reflow methods. The broken sludge reflowed to the anaerobic zone reduced the sludge production of the anaerobic anoxic oxic system by 51.3%.
engineering, environmental, chemical
What problem does this paper attempt to address?
The paper aims to study the effects of ultrasonic/ozone pretreatment on residual sludge and its impact on the anaerobic-anoxic-oxic (A/A/O) system of municipal wastewater treatment plants. Specifically, the paper explores the following issues: 1. **Optimization of ultrasonic/ozone pretreatment conditions**: - The study determined the optimal ultrasonic intensity (1.61 W/mL) and ozone dose (0.14 g·O₃/g·SS) through response surface methodology, achieving a maximum sludge reduction rate of 68.1%. 2. **Evaluation of the biodegradability of pretreated sludge**: - The study found that the biodegradability of sludge improved after ultrasonic/ozone treatment, as evidenced by changes in specific oxygen uptake rate (SOUR). 3. **Impact of pretreated sludge recirculation on A/A/O system performance**: - The paper analyzed the effects of recirculating pretreated sludge to different stages of the A/A/O system (anaerobic zone, anoxic zone, mixed zone) on effluent quality (chemical oxygen demand COD, total nitrogen TN, ammonia nitrogen NH₃-N, total phosphorus TP) and sludge production. - The results showed that recirculating pretreated sludge had a slight negative impact on COD removal rate, but overall it remained around 89%; however, the removal rates of TN and TP significantly improved, with TN removal rate increasing by 13.2%. 4. **Sludge reduction effect**: - When all pretreated sludge was recirculated to the anaerobic zone, the system's sludge production decreased by 51.3%, demonstrating a good sludge reduction effect. In summary, the paper mainly addresses how to improve the reduction efficiency of residual sludge through ultrasonic/ozone pretreatment and explores the specific impact of this pretreatment method on the performance of the A/A/O system.