Proceeding of the International Digital Dentistry Society World Congress, Baden Baden 2019
DOI: https://doi.org/10.1186/s12903-019-0954-7
2019-12-01
BMC Oral Health
Abstract:<span> Background: Biomodeling in integration with digital imaging techniques such as intra-oral scanning and cone-beam computerized tomography (CBCT) is being commonly practiced in dental implantology for pre-operative treatment planning, clinical teaching and evaluating bone density and drilling techniques. The objective of following study was to assess the quantitative accuracy of CBCT-derived mandibular biomodels.Methods: A CBCT dataset was segmented and mandible was isolated. Fifteen mandibular biomodels were fabricated utilizing multijet (MJ=4), digital light processing (DLP=4), stereolithography (SLA=2), fused deposition modeling (FDM=2), colorjet (CJ=2) and selective laser sintering (LS=1) based high-end commercial and in-house printers. Printed models were superimposed onto the original mandible for comparing surface accuracy. A part comparison analysis with color-coded map was carried out for evaluating the difference between each printed and original model surface.Results<strong class="EmphasisTypeBold">:</strong> MJ technology showed least amount of error associated with both erupted and impacted teeth. Highest bony surface accuracy was achieved with SLA and LS based biomodels. Trabecular structures were most accurately printed with MJ printers. FDM technology had the highest overall absolute mean error associated with both teeth and bone. No significant differences were observed between each surface of original and printed models.Conclusions: Overall biomodels were able to well replicate skeletal and dental anatomical surfaces. However, some models showed shortcomings in relation to depicting trabecular architecture which might influence bone density for drilling bone and placing dental implants. Background. On the base of the state of the art on the applications of augmented reality (AR) in dentistry from previous studies a new system was developed and <em class="EmphasisTypeItalic">in vivo</em> tested with Institutional Review Board approval of the Ethics Committee of Policlinico of Milan (n. 421). The purpose of the new system is to provide a new light, portable hand-held smart device which provides a compound superimposed dynamic vision of the anatomical structures of the patient, radiologic exams and digitally positioned medical devices for AR-guided operations.Methods. CBCT data and the .stl files of miniscrews (TADs), (Leone, Firenze, Italy), were imported in a dicom viewer, placed in the correct position and fixed, then exported to .stl format separately. The digital images were uploaded to a server and opened with a smart, light hand-held hardware. The hardware was placed in front of the patient placed in N.H.P and the new software was started. Superimposition was regulated with pinch gesture on the touch screen until correct positioning of the frontal teeth of the patient, the opacity of digital images were regulated with a function of the software. The superimposition was automatically stabilized by a function of the software using software development kit (SDK) engines. Tads were placed under the guide of the compound vision. Time measurements were taken on superimposition by different operators and the error was calculated with a digital caliper.Results. The new system provided effectively a dynamic functional compound superimposition of anatomical structures and previously digitally placed medical devices. The error in the positioning of the TADs was calculated as < of 0.3 mm for both while time measurements of the superimposition session were less than 5 minutes for each session.Conclusions. The new proposed system effectively provides a simple and light dynamic AR superimposition of digital data on a surgical site providing the clinician a compound vision of anatomical structures. The TADs were placed with AR assisted surgery with a acceptable error, further in vivo and in vitro studies are needed. Purpose. Modern implantology has been focused on the peri-implant mucosa maturation patterns, with particular attention on the frontal area, aiming to obtain an optimal aesthetic result. The purpose of the following study is to analyze height/width proportion in the peri-implant buccal tissues between two different types of connection: Flat to Flat and Magic Five Cone Morse Connection (Anyridge®).Methods. The present study analyzes 294 implants, the measurements were done with digital 3D technology at one year from the provisional crown placement. Every single implant was matched with its own Scan Body and was scanned with 3Shape D700, in order to obtain a tridimensional section of the model. Peri-implant measurements included the width of the peri-implant mucosa (HV), calculated from the implant connection to the buccal mucosa surface on a line perpendicular to the main implant axis. For the height of the peri-implant tissues (VV), we considered as well, the same geometrical line as the apical point of the measure to <p>-Abstract Truncated-</p>
dentistry, oral surgery & medicine