Increased Patient Satisfaction and a Reduction in Pre-Analytical Errors Following Implementation of an Electronic Specimen Collection Module in Outpatient Phlebotomy

Michalis Kantartjis,Stacy E F Melanson,Athena K Petrides,Adam B Landman,David W Bates,Bernard A Rosner,Ellen Goonan,Ida Bixho,Milenko J Tanasijevic
DOI: https://doi.org/10.1093/labmed/lmx024
IF: 1.865
2017-07-25
Laboratory Medicine
Abstract:BACKGROUND: Patient satisfaction in outpatient phlebotomy settings typically depends on wait time and venipuncture experience, and many patients equate their experiences with their overall satisfaction with the hospital.METHODS: We compared patient service times and preanalytical errors pre- and postimplementation of an integrated electronic health record (EHR)-laboratory information system (LIS) and electronic specimen collection module. We also measured patient wait time and assessed patient satisfaction using a 5-question survey.RESULTS: The percentage of patients waiting less than 10 minutes increased from 86% preimplementation to 93% postimplementation of the EHR-LIS (P ≤.001). The median total service time decreased significantly, from 6 minutes (IQR, 4-8 minutes), to 5 minutes (IQR, 3-6 minutes) (P = .005). The preanalytical errors decreased significantly, from 3.20 to 1.93 errors per 1000 specimens (P ≤.001). Overall patient satisfaction improved, with an increase in excellent responses for all 5 questions (P ≤.001).CONCLUSIONS: We found several benefits of implementing an electronic specimen collection module, including decreased wait and service times, improved patient satisfaction, and a reduction in preanalytical errors.