Influence of different loads on PCDD/F removal by SCR during municipal solid waste incineration

Jiayao Wu,Yuxuan Ying,Yunfeng Ma,Sen Zheng,Xiaoqing Lin,Xiaodong Li,Jianhua Yan
DOI: https://doi.org/10.1016/j.chemosphere.2023.139516
IF: 8.8
2023-07-21
Chemosphere
Abstract:This study was conducted on a full-scale (500 t/d) municipal solid waste incinerator (MSWI), investigating the influence of different loads on the emission of polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDD/Fs) and their removal by selective catalytic reduction (SCR) system. The total concentration of PCDD/Fs at the SCR inlet under 100% load was higher than that under 80% load. The changing loads caused different distribution characteristics of PCDD/Fs at the SCR inlet, and the dominant congeners changed from high-chlorinated PCDDs (80% load) to low-chlorinated PCDFs (100% load). Moreover, the increased load enhanced the removal efficiency of PCDD/Fs by SCR from 17.3% to 64.2%, which was influenced by the inlet PCDD/F distribution and the moisture content. The high-chlorinated PCDD/Fs with the more stable structure were more difficult to be deteriorated and the high moisture content can weaken the catalytic activity of SCR catalysts. Correlation analysis was used to study the relationship between major air pollutants and PCDD/F emissions. The results showed that HCl positively correlated with PCDD/F emission concentrations, while NO x and SO 2 negatively correlated. The results of this study can provide a reference for MSWI to operate properly under variable loads.
environmental sciences
What problem does this paper attempt to address?