Microsoft Word-Manuscript rev2

Juan Qiu,Minghui Tang,Yaqi Peng,Shengyong Lu,Xiaodong Li
2020-01-01
Abstract:Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the flue gas from two 10 types of waste incinerators (municipal solid waste incinerators and hazardous waste incinerators) 11 the most commonly used in China were investigated in this study. The PCDD/F emissions from 12 the stack gas of the waste incinerators showed a large variation from 0.016 to 0.29 ng I-TEQ∙m-3 13 with an average value of 0.103 ng I-TEQ∙m-3. The emission factors of PCDD/Fs were in the 14 range of 0.056-0.607 μg I-TEQ∙t-1 (average 0.235 μg I-TEQ∙t-1) for municipal solid waste 15 incinerators (MSWIs) and 0.07-3.27 μg I-TEQ∙t-1 (average 1.03 μg I-TEQ∙t-1) for hazardous waste 16 incinerators (HWIs), respectively. It was estimated that 10.2-88.0 mg I-TEQ (average 35.0mg 17 I-TEQ) and 1.13-53.0 mg I-TEQ (average 17.1 mg I-TEQ) of PCDD/Fs were annually released to 18 the atmosphere, respectively from MSWIs and HWIs. The level and congener patterns of 17 19 species of PCDD/Fs in the ambient air and in soil samples around the MSWIs and HWIs were 20 investigated to evaluate the influence of PCDD/F emission on the environment. The PCDD/F 21 concentrations in the ambient air from the 5 MSWIs and 4 HWIs ranged from 0.088 to 13.9 pg 22 I-TEQ∙m-3 with an average value of 0.185 pg I-TEQ∙m-3. The soil samples in the vicinity of 23 MSWIs and HWIs presented concentrations between 0.68 and 16.0 ng I-TEQ·kg−1 with an 24 average value of 3.98 ng I-TEQ∙kg-1. This study showed that PCDD/F emission from the 25 incineration plants had an obvious impact on the surrounding ambient air. 26
What problem does this paper attempt to address?